7.8 Pneumatic Unit
DA8MEC-Z0-300-A0
7.8-2
7.8.2 Main Regulator
Unit No. N610060943AA
Inspection
Period
No.
Item Task Description
a.
Main pressure Make sure that air pressure is at 0.5 MPa.
Daily
b.
Pneumatic circuit
Make sure that there is no air leakage.
Hand valve
Air input
To machine
Air supply unit
b. Main pressure
RL131
MAINTENANCE MANUAL
7.9 Covers
DA8MEC-Z0-200-A0
7.9-1
7.9. Covers
DA8MEC-Z0-200-A0
7.9.1 Cover Unit
Unit No. N610052017AA
Oiling
Period
No.
Item Task
Oiling
volume
Description
1.
Collar
(2 positions: left/right)
2.
Collar
(2 positions: left/right)
3.
Collar
(2 positions: left/right)
4.
Collar
(2 positions: left/right)
Position: Sliding surface
3
months
5.
Hinge
1 to 2
drops
each
Position: Clearances of 25 mm intervals
=REMARKS=
Do not apply grease to the rod of the gas dumper.
Doing so may cause foreign matter to mix in the gas, leading to gas leakage.