11.1 Material Safety Data Sheet
DA8MEC-4E-010-A0
11.1-11
Accidental Release Measures
Precaution for human body
Wear the fire-proof protective gears.
Precaution for environmental protection
14.
1. Be careful not to allow oil to enter drains or water courses.
2. For a leak on the sea, chemical absorbent must comply with the technical requirements of the regulations
of relevant authorities.
How to clean up leakage
15.
1. Remove all ignition sources immediately.
2. For a small leak, collect the leaked grease by removing with a spatula or shovel or by absorbing with sand
or waste cloth, etc. Then wipe up completely with a waste cloth.
3. For a large leak, evacuate the nearby area and rope off to prevent entry. Stop the leakage with sand, etc.
and lead to a safe place, then collect it in an empty container.
4. For a leak on the sea, deploy oil booms to prevent spreading. Scoop up or soak up with absorbing mat.
Chemical adsorbent must comply with the technical requirements of the regulations of relevant authorities.
Preventive measures against second disaster
16.
1. In the event of a leak, report it to local authorities immediately to prevent fires or accidents from occurring
or spreading.
2. Remove all ignition sources immediately, and prepare the fire extinguishing agents.
Precautions in Handling and Storage
Handling
Technical measures
17.
1. When handling more than the specified amount, handle the product in a location of manufacture or
warehouse that meets the standards required by the law.
2. Prevent contact with flames, sparks or hot objects and do not evaporate needlessly.
3. Take measures against static electricity and wear conductive clothing and boots.
4. Before repairing or modifying the machinery and equipment in which hazardous substance remains,
eliminate the substance completely in a safe place.
5. Do not eat or drink.
6. Wear appropriate safety gear to prevent contact with skin or eyes.
7. If mists are generated, wear a respirator so as not to inhale them.
8. Keep containers tightly closed.
Precaution
Vapors generated from petroleum product often stay in the air because vapor is heavier than air. It is,
therefore, necessary to ventilate the workplace and to keep away from flames.
Safety handling precaution
18.
1. Use the grease at room temperature. Avoid entry of moisture or foreign substances.
2. Avoid contact with halogens, strong acids, alkaline materials or oxidizers.
Storage
Appropriate storage condition
19.
1. Store in a well-ventilated place where not exposed to direct sunlight.
2. Label as a hazardous product.
3. Avoid contact with heat, sparks, flames and buildup of static electricity.
Appropriate technical measures
Electric appliances used in the storage place should be explosion-proof and need to be grounded.
Avoid contact with or storing in the same place as halogens, strong acids, alkaline materials or oxidizers.
RL131
MAINTENANCE MANUAL
11.1 Material Safety Data Sheet
DA8MEC-4E-010-A0
11.1-12
Safe packaging container material
20.
1. Do not pressurize empty containers.
2. Do not weld, heat, drill or cut containers. Residue can catch fire with an explosion.
Disposal Consideration
21.
1. Business owners should dispose of industrial wastes by themselves, or entrust the disposal to the
specialists approved by the governor or to the local authorities responsible.
2. Do not dump into any sewers, on ground, or into any body of water.
3. Burn in an incinerator before disposing of in a landfill. Burnt residue must be below the criteria stipulated in
the law on waste disposal and cleaning.
4. Burn in a safe place in a manner where there is no possibility of hazard to others or damage to properties.
A guard must be placed.
RL131
MAINTENANCE MANUAL
11.1 Material Safety Data Sheet
DA8MEC-4E-010-A0
11.1-13
11.1.6 MOBILUX 2
Oil name: MOBILUX 2
Manufacturer’s name: Exon Mobil Corporation
First Aid Measures
Eye contact
Immediately flush with plenty of clear water. Consult a physician.
Skin contact
Flush contacted areas abundantly with soap and water.
Inhalation
Remove to fresh air.
Warm with blankets or other means and repose. Consult a physician if necessary.
Ingestion
Do not induce vomiting. Promptly consult a physician.
Wash out mouth with water.
Fire Fighting Measures
How to extinguish
22.
1. Put out the sources of fire.
2. For fires at earlier stage, use dry chemical or carbon dioxide to douse.
3. For large fires, it is effective to use fire foam to block off air. Water spray can spread fire and hazardous
situation may result.
4. Spray the surrounding equipment with large amounts of water to cool.
5. Use water spray from upwind of fire and wear protective gears.
6. Prevent unauthorized entry to the fire area.
Fire extinguishing agents
Loaded stream fire extinguisher, foam, dry chemical and carbon dioxide.
Do not use water jet.
Accidental Release Measures
Remove the sources of ignition.
23.
1. Large leak: Evacuate the nearby area and rope off the area to prevent entry.
Be sure to wear protective gears. Stop the leaked grease with sand, etc. and lead to a safe place, then
collect it in an empty container. Be careful not to allow oil to enter drains or water courses.
2. Small leak: Collect the leaked grease in an empty container by removing with a spatula or shovel or by
adsorbing with sand or waste cloth, etc. Then wipe up completely with a waste cloth.
3. Leak on the sea: Deploy oil booms to prevent spreading. Scoop up or soak up with absorbing mat.
Chemical adsorbent must comply with the technical requirements of the regulations of relevant authorities.