RL131 MAINTENANCE MANUAL 11.1 Material Saf ety Data S heet DA8MEC-4E-01 0-A0 1 1.1-21  Precautions in Han dling and Stor age  Handling Technical measures W ear protective gears if the re is a risk of skin contact. Keep…

100%1 / 250
RL131
MAINTENANCE MANUAL
11.1 Material Safety Data Sheet
DA8MEC-4E-010-A0
11.1-20
11.1.10 Klubersynth GH6-320
Oil name: Klubersynth GH6-320
Manufacturer’s name: NOK Corporation
First Aid Measures
Inhalation
If a large amount is inhaled, move victim to fresh air immediately, and keep warm and still. Consult a
physician if necessary.
Skin contact
Wipe off with a cloth and flush with water and soap.
If itchiness or inflammation is present, consult a physician promptly.
Eye contact
Firstly flush with clean water for at least 15 minutes, consult a physician.
Ingestion
Do not induce vomiting. Consult a physician promptly.
Fire Fighting Measures
How to extinguish
Loaded stream fire extinguisher, foam, carbon dioxide and dry chemical.
Do not use water jet.
Specific fire fighting measures
Remove all ignition sources. Wear protective gears to extinguish.
Protection for fire fighters
Use a respirator to avoid inhaling harmful gas. Approach from upwind of the fire.
Accidental Release Measures
Precaution for human body
Wear protective gears to prevent exposure, inhalation of vapor and contact with skin.
Well-ventilate the room if necessary.
Prevent unauthorized entry to the leakage area.
Remove all ignition sources, hot objects, and inflammable material. Prepare a fire extinguisher.
Precaution for environmental protection
To prevent drainage containing this product from discharging to public water or seeping underground, do not
wash away the spillage on the floor.
How to clean the oil
For a small leak, collect the oil by using a spatula or a shovel, or soak into soil etc. Then wipe with waste
cloth completely.
Use safety appliances without sparks.
For a large leak, first prevent spreading by using earth and sand, and then collect the oil.
RL131
MAINTENANCE MANUAL
11.1 Material Safety Data Sheet
DA8MEC-4E-010-A0
11.1-21
Precautions in Handling and Storage
Handling
Technical measures
Wear protective gears if there is a risk of skin contact.
Keep away from flame and sparks. Electric appliances should be explosion-proof, and take measures on
electrostatics and ignition sources with sparks.
Precaution
Handle at room temperature. Avoid entry of moisture or foreign substances.
Safety handling precaution
Wear protective gears to prevent exposure, inhalation of vapor and contact with skin.
Storage
Appropriate storage condition
Store in sealed container in dry, dark place with adequate ventilation.
For other storage conditions, follow the fire defense law, occupational health and safety law, etc.
Disposal Consideration
29.
1. Entrust the disposal to the specialists approved by the governor.
2. Dispose en empty container after cleaning the contents completely.
3. Dispose of properly in accordance with laws and regulations.
RL131
MAINTENANCE MANUAL
11.1 Material Safety Data Sheet
DA8MEC-4E-010-A0
11.1-22
11.1.11 Mobil SHC 632
Oil name: Mobil SHC 632
Manufacturer’s name: Exon Mobil Corporation
First Aid Measures
Eye contact
Immediately flush with plenty of clear water. Consult a physician.
Skin contact
Flush contacted areas abundantly with soap and water.
Inhalation
Remove to fresh air.
Warm with blankets or other means and repose. Consult a physician if necessary.
Ingestion
Do not induce vomiting. Promptly consult a physician.
Wash out mouth with water.
Fire Fighting Measures
How to extinguish
30.
1. Put out the sources of fire.
2. For fires at earlier stage, use dry chemical or carbon dioxide to douse.
3. For large fires, it is effective to use fire foam to block off air.
Water spray can spread fire and hazardous situation may result.
4. Spray the surrounding equipment with large amounts of water to cool.
5. Approach from upwind of fire and wear protective gears.
6. Prevent unauthorized entry to the fire area.
Fire extinguishing agents
Loaded stream fire extinguisher, foam, dry chemical and carbon dioxide.
Do not use water jet.
Accidental Release Measures
Remove the sources of ignition.
31.
1. Large leak: Evacuate the nearby area and rope off the area to prevent entry.
Be sure to wear protective gears. Stop the leaked grease with sand, etc. and lead to a safe place, then
collect it in an empty container. Be careful not to allow oil to enter drains or water courses.
2. Small leak: Collect the leaked grease in an empty container by removing with a spatula or shovel or by
adsorbing with sand or waste cloth, etc. Then wipe up completely with a waste cloth.
3. Leak on the sea: Deploy oil booms to prevent spreading. Scoop up or soak up with absorbing mat.
Chemical adsorbent must comply with the technical requirements of the regulations of relevant authorities.
4. In the event of a leak, report it to local authorities immediately to prevent fires or accidents from occurring