Maintenance Manual - 第58页
RL1 31 MAINTENANCE MANUAL 3.1 O utline of I nstall ation DA8ME C-11-010- A0 3.1- 5 3.1. 7 Connecting the A ir S uppl y Connect t he prim ary air pi ping to the m achine. Make sure t hat t he prim ary a i r pressure is m …

RL131
MAINTENANCE MANUAL
3.1 Outline of Installation
DA8MEC-11-010-A0
3.1-4
3.1.5 Removing Fixing Brackets (Red)
This machine is delivered with the X-Y table, Z axis and Z covers secured with the fixing brackets (Red) to
prevent them from moving during transport.
Before starting up the machine, remove all the fixing brackets in the photos below.
Store the removed fixing brackets.
1.
1. XY table unit
3.1.6 Noise Measurement
Here is the noise data of the machine measured at each point as shown below.
Measured Points
=REMARKS=
↔ : Distance 1 m each
Noise Data
Point A B C D E F G H I J K L M N O P
Measured
value
(dB (A) )
71.0 72.0 73.0 74.0 74.0 75.0 71.0 72.0 72.0 71.0 70.0 71.0 74.0 72.0 72.0 71.5
Dark noise: 29.5 dB (A)
Product No.: 108710403301 (x 1)
(Plane view) (Side view)
AB
C
D
E
F
GH I J K
L
M
N
O
P

RL131
MAINTENANCE MANUAL
3.1 Outline of Installation
DA8MEC-11-010-A0
3.1-5
3.1.7 Connecting the Air Supply
Connect the primary air piping to the machine.
Make sure that the primary air pressure is more than 0.5 MPa and the flowrate more than 80 NL/min
(A.N.R).
=REMARKS=
The primary air shall have no foreign substance such as moisture.
After completing the piping connection, supply the primary air, and adjust it to 0.5 MPa using the MR unit.

RL131
MAINTENANCE MANUAL
3.1 Outline of Installation
DA8MEC-11-010-A0
3.1-6