00193786-01 - 第114页

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual Page 114 of 236 ©Siemens AG, all rights reserved 4.7.11 S5F73 - Alarm Report Block Acknowledge S 5 F 7 3 [ W ] * H < - E <L [3] <U4 ALID> * ALID - Alarm…

100%1 / 236
SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 113 of 236
4.7.9 S5F71 - Alarm Report Block Send
S5F71 [W] * H<-E
<L [2]
<U1 0> * ALPY Alarm Priority
<L [1]
<L [4]
<U4 ALID> * ALID - Alarm ID
<BOOLEAN ASTAT> * T = Alarm On
F = Alarm Off
<U4 ASER> * ASER Alarm Serial Number
<A [16] 'YYYYMMDDhhmmsscc'> * CLOCK
>
>
> .
Note: This message is provided only for compatibility with Host computers which support
an older version of GEM.
If the Equipment Constant "ConfigAlarms" is set to "1", the Equipment sends S5F71
instead of the normal S5F1 Alarm Notification Send.
The SIPLACE reports that an alarm condition has changed.
ALID identifies the Alarm.
ASTAT value is "True" (Non-zero) if this alarm is currently On (Unsafe), or "False" (Zero)
if it is currently Off (Safe).
ASER (Alarm Serial Number) is assigned by the Equipment. Its value begins at "1" and
is incremented by 1 for each alarm reported.
ALPY (Alarm Priority) is always zero.
CLOCK indicates the date and time of the alarm change.
Equipment Constant "Wbits5" controls whether the Equipment sends S5F71 with w-bit =
"1" (Reply Expected) or "0" (No Reply Expected).
4.7.10 S5F72 - Alarm Report Block Acknowledge
S5F72 * H->E
<L> .
The Host acknowledges Alarm Report. This Equipment ignores the data portion of
S5F72.
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 114 of 236 ©Siemens AG, all rights reserved
4.7.11 S5F73 - Alarm Report Block Acknowledge
S5F73 [W] * H<-E
<L [3]
<U4 ALID> * ALID - Alarm ID
<BOOLEAN ASTAT> * T = Alarm On,
F = Alarm Off.
<A [16] 'YYYYMMDDhhmmsscc'> * TIMESTAMP
> .
Note: This message is provided only for compatibility with older Host computers which
support GEM 3.1.
In order for this message to be used, the Equipment Constant "ConfigAlarms" must be
set to "2".
The SIPLACE reports that an alarm condition has changed.
ALID identifies the Alarm.
ASTAT value is "True" (Non-zero) if this alarm is currently On (Unsafe), or "False" (Zero)
if it is currently Off (Safe).
TIMESTAMP indicates the date and time of the alarm change.
Equipment Constant "WBitS5" controls whether the Equipment sends S5F73 with W-Bit
"1" (Reply Expected) or "0" (No Reply Expected).
4.7.12 S5F74 - Alarm Notification Acknowledge
S5F74 * H->E
<B [1] ACK5> .
The Host acknowledges Alarm Report. This Equipment ignores ACKC5.
SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 115 of 236
4.8 Stream 6
4.8.1 S6F1 - Trace Data Send
S6F1 [W] * H<-E
<L [4]
<U4 TRID> * Trace ID
<U4 SMPLN> * Sample Number
<A 'yyyymmddhhmmss'> * STIME - Sample Date and Time
<L
<V> * Variable Value
...
>
> .
The Equipment sends time driven trace data, as previously requested by the Host using
S2F23.
TRID is the Trace ID as initiated by the Host.
SMPLN is the sample number. The first sample is "1", the next "2", and so on. If
REPGSZ is greater than 1, SMPLN is the number of the last sample contained in this
S6F1.
STIME is the date and time at which this sample was taken. If REPGSZ is greater than
1, STIME is the date and time of the last sample contained in this S6F1.
The V's appear in the same order they were specified in S2F23.
S6F1 is normally single block. However, if the Host erroneously initiates a multiblock
trace using an incorrect S2F23, S6F1 may be multi-block. The Equipment never sends
an Inquire/Grant message preceding S6F1.
Equipment Constant "WBitS6" controls whether the Equipment sends S6F1 with W-Bit
"1" (Reply Expected) or "0" (No Reply Expected).
4.8.2 S6F2 - Trace Data Acknowledge
S6F2 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the data. The Equipment ignores ACKC6.
4.8.3 S6F3 - Annotated Event Report
S6F3 [W] * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 DSID> * DSID=RPTID Report ID
<L