SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual ©Siemens AG, all rights reserved page 121 of 236 If the CEID is enabled, but no Reports are lin ked to this CEID, S6F11 has the following special format: S 6 F 1 3 …

100%1 / 236
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 120 of 236 ©Siemens AG, all rights reserved
4.8.10 S6F13 - Annotated Event Report Send
S6F13 W * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 RPTID> * Report ID
<L
<L [2]
<U4 VID> * Variable ID
<V> * Variable Value
>
...
>
>
...
>
> .
Note: This message is provided only for compatibility with older Host computers which
support older versions of GEM.
A Collection Event has occurred at the Equipment. The Host has enabled event
reporting for this CEID (see S2F37). The Host has set the Equipment Constant RpType
to "True" (Annotated report format desired). The Equipment Constant ConfigEvents has
been set to 1. The Equipment sends one or more Event Reports which the Host has
previously linked to that CEID (see S2F35). Each report contains specific Variables
which the Host has previously defined for that Report (see S2F33).
The Equipment generates a value for DATAID to uniquely identify this Conversation. If
S6F11 is multiblock, the Equipment first sends the S6F5/S6F6 Inquire/Grant transaction,
and the DATAID in S6F11 will match DATAID in S6F5.
SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 121 of 236
If the CEID is enabled, but no Reports are linked to this CEID, S6F11 has the following
special format:
S6F13 W * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
4.8.11 S6F14 - Annotated Event Report
S6F14 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the Event Report. The Equipment ignore ACKC6.
4.8.12 S6F15 - Event Report Request
S6F15 W * H->E
<U4 CEID> . * Collection Event ID
The Host sends the CEID of interest, requesting normal format reports.
4.8.13 S6F16 - Event Report Data
S6F16 * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 RPTID> * Report ID
<L
<V> * Variable Value
...
>
>
...
>
> .
The Equipment sends one or more Event Reports which the Host has previously linked to
that CEID (see S2F35). Each report contains specific Variables which the Host has
previously defined for that Report (see S2F33).
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 122 of 236 ©Siemens AG, all rights reserved
This message occurs whether or not the Host has enabled event reporting for this CEID
(see S2F37), and regardless of how the Host has set the Equipment Constant RpType
(report format).
The Equipment generates a meaningless value for DATAID.
CEID contains the CEID specified in S6F15.
If the CEID specified in S6F15 is invalid, or if no reports are linked to this CEID, this
message has the following special format:
S6F16 * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
4.8.14 S6F17 - Annotated Event Report Request
S6F17 W * H->E
<U4 CEID> . * Collection Event ID
The Host sends the CEID of interest, requesting annotated format reports.
4.8.15 S6F18 - Annotated Event Report Data
S6F18 * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 RPTID> * Report ID
<L
<L [2]
<U4 VID> * Variable ID
<V> * Variable Value
>
...
>
>
...
>
> .