00193786-01 - 第150页
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual Page 150 of 236 ©Siemens AG, all rights reserved 5.4.7 Operator Command, Successful Step SECS Message Description 1. ControlState is Local . The operator issues a f…

SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 149 of 236
1. H -> E S2F41 [W] The Host sends the command. The W-bit in this
message may be either 0 or 1.
2. H <- E S2F42 If the W-bit in S2F41 is 1, the Equipment
acknowledges the command. The acknowledge
code in this message is 64 (Control State is
incorrect). If the W-bit is 0, this message is not
sent. In either case, the Equipment does not
perform the command.
5.4.5 Go Remote, Operator-Initiated
Step SECS Message Description
1. ControlState is Local. The Equipment operator
switches the Equipment to Remote Control.
2. H <- E S6F11 W The Equipment signals CEID GemControlState
REMOTE. Event Reports as appropriate.
3. H -> E S6F12 The Host acknowledges the report.
5.4.6 Go Local, Operator-Initiated
Step SECS Message Description
1. ControlState is Remote. The Equipment
operator switches the Equipment to Local
Control.
2. H <- E S6F11 W The Equipment signals CEID GemControlState
LOCAL. Event Reports as appropriate.
3. H -> E S6F12 The Host acknowledges the report.

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 150 of 236 ©Siemens AG, all rights reserved
5.4.7 Operator Command, Successful
Step SECS Message Description
1. ControlState is Local. The operator issues a
front-panel INITIATE PROCESS command. The
Equipment performs the command.
2. H <- E S6F11 W The Equipment signals CEID LotStart. Event
Reports as appropriate.
3. H -> E S6F12 The Host acknowledges the report.

SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 151 of 236
5.5 Process Program
Process Program supply via GEM will be implemented in a later stage.
5.6 Equipment Terminal Communications
5.6.1 Host to Equipment, Single Line
Step SECS Message Description
1. The Host has data to display at the Equipment’s
front panel.
2. H -> E S10F3 [W] Terminal Display. The Host sends text. The
Equipment displays the text on its front panel.
3. H <- E S10F4 If the W-bit in S10F3 is 1, the Equipment
acknowledges.
4. The Operator acknowledges that he/she has
read the message.
5. H <- E S6F11 W The Equipment signals CEID S10Ack. Event
Reports as appropriate.
6. H -> E S6F12 The Host acknowledges the report.
5.6.2 Host to Equipment, Multi-Line
Step SECS Message Description
1. The Host has a multi-line data to display at the
Equipment front panel.
2. H -> E S10F5 [W] Terminal Display Multiple. The Host sends text.
The Equipment displays the text on its front
panel.
3. H <- E S10F6 If W-bit in S10F5 is 1, the Equipment
acknowledges.
4. The Operator acknowledges that he/she has
read the message.
5. H <- E S10F11 W The Equipment signals CEID HostMsgAck.
Event Reports as appropriate.
6. H -> E S6F12 The Host acknowledges the report.
5.6.3 Equipment Sends Text to Host
Step SECS Message Description
1. The Equipment operator enters data to send to
the Host.
2. H <- E S10F1 [W] Equipment sends text to Host. The W-bit in this
message may be either 0 or 1. The Host
displays the message for the operator.
3. H -> E S10F2 If the W-bit in S10F1 is 1, the Host
acknowledges the text message.