00193786-01 - 第161页
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual ©Siemens AG, all rights reserved page 161 of 236 VID Class Format Name and Description 612008 SV I4 TWINTRANSPORTWIDTH transport width [1/1000 mm] on twin side A va…

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 160 of 236 ©Siemens AG, all rights reserved
VID Class Format Name and Description
0 = Empty
1 = Full
2 = Error
612003 SV U1 OUTPUTCONVEYORSTATE.
The state of output conveyor.
0 = Empty
1 = Full
2 = Error
612004 SV U1 TWININPUTCONVEYORSTATE.
The state of the input conveyor on twin side
0 = Empty
1 = Full
2 = Error
612022 SV U1 TWINFIRSTPROCESSINGCONVEYORSTATE
The state of the first processing conveyor on twin side
0 = Empty
1 = Full
2 = Error
612023 SV U1 TWININTERMEDIATECONVEYORSTATE
The state of the intermediate conveyor on twin side
0 = Empty
1 = Full
2 = Error
612024 SV U1 SECONDPROCESSINGCONVEYORSTATE
The state of the second processing conveyor on twin
side
0 = Empty
1 = Full
2 = Error
612006 SV U1 TWINOUTPUTCONVEYORSTATE.
The state of output conveyor on twin side.
0 = Empty
1 = Full
2 = Error
612007 SV I4 TRANSPORTWIDTH
transport width [1/1000 mm]
A value of -1 indicates an error
Only valid after width has been measured or adjusted
by line computer

SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 161 of 236
VID Class Format Name and Description
612008 SV I4 TWINTRANSPORTWIDTH
transport width [1/1000 mm] on twin side
A value of -1 indicates an error
Only valid after width has been measured or adjusted
by line computer
Matrix Tray Changer (MTC)
812002 SV L MTCINFO
<L
<U1 MTC_number> valid for all MTC Events
<I2 tower>
<I2 carrier_modul>
<I2 level>
<I2 division>
<I4 Filling_level>
>
If you have several MTCs you can identify a MTC by
MTC_number. A MTC has 2 towers (1,2) and on every
tower there are several carrier modules. A carrier
module contains several tray carriers. Each tray
carrier can be identified by a level number. A tray
carrier consists of many divisions, wich can be
identified by the division number.
Filling_level is only valid with the Event
MTCfillLevelChanged.
In case of the Event MTCfillLevelChanged
carrier_modul will be -1.
Barcode
912002 SV A BCININPUTCONVEYOR
Barcode read from PCB in input conveyor. If no
barcode reader is installed in SIPLACE this variable
will contain an empty text
An empty text indicates an error.
912003 DV A COMPONENTBARCODE
Component barcode is read by the GUI.
An empty text indicates an error or barcode is read by
Mobile Verifier
912004 DV U2 WAYOFINPUTCOMPONENTBARCODE
Way of reading the component barcode:
1: with keyboard
2: with barcode reader
3: no barcode read

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 162 of 236 ©Siemens AG, all rights reserved
VID Class Format Name and Description
Is not valid for Mobile Verifier
912005 SV U2 PCBSIDEININPUTCONVEYOR
Side of the PCB showing the barcode (only valid in
case of two barcode reader per conveyor)
1: above
2: down
3: barcode reader manufctured by LEUTZE in use or
the barcode could not be read
912006 SV U2 PCBSIDEINCENTERCONVEYOR
Side of the PCB showing the barcode (only valid in
case of two barcode reader per conveyor)
1: above
2: down
3: barcode reader manufctured by LEUTZE in use or
the barcode could not be read
912012 SV A BCINTWININPUTCONVEYOR
Barcode read from PCB in twin input conveyor. If no
barcode reader is installed in SIPLACE this variable
will contain an empty text.
An empty text indicates an error.
912015 SV U2 PCBSIDEINTWININPUTCONVEYOR
Side of the PCB showing the barcode (only valid in
case of two barcode reader per conveyor)
1: above
2: down
3: barcode reader manufctured by LEUTZE in use or
the barcode could not be read
912017 EC U1 BCREADEREXIST
Unables/Enables the event messages of the BCread
and BCTwinRead events.
0: No BCread and BCTwinRead events send
1: BCread and BCTwinRead events send (default)
912021 SV A PCBBCProc1Conv1
Barcode of PCB in progress in processing area 1 on
conveyor 1.
If no barcode reader is installed or no PCB is in
progress this variable will contain an empty text.
912021 SV A PCBBCProc1Conv2
Barcode of PCB in progress in processing area 1 on
conveyor 2.
If no barcode reader is installed or no PCB is in
progress this variable will contain an empty text.