00193786-01 - 第172页
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual Page 172 of 236 ©Siemens AG, all rights reserved VID Class Format Name and Description automatically reseted when a PCB reaches the corresponding processing conveyo…

SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 171 of 236
VID Class Format Name and Description
activ
1002943 EC U1 SAFE_SPOOL_MODE
0 = inactiv
1 = aktiv
GUI
1122001 SV A GUIACTIONTEXT
Last „Action text“ sent to GUI
An empty text indicates an error
1122002 SV A GUISTATETEXT
Last „State text“ sent to GUI
An empty text indicates an error
1122007 SV U4 GUIMESSAGENUMBER
Used for General GUI Events CEID 1120300 and
1120301
Contains the CEID of the special GUI Event.
E.g. in case of GUIStart you may use either Event
1120007 GUIStart or Event MessageFromGuiGeneral
with VID 1122007 (GUIMESSAGENUMBER) which
will contain the value 1120007.
13xxxxx
14xxxxx
23xxxxx
24xxxxx
SIPLACE Head 1
SIPLACE Head 2
SIPLACE Head 3
SIPLACE Head 4
1312001
1412001
2312001
2412001
SV I4 HEIGHTHEAD1
HEIGHTHEAD2
HEIGHTHEAD3
HEIGHTHEAD4
Height of placement head x.
Only valid after reference run. Units are 1/1000 mm
During the reference run the SIPLACE measures the
distance between the upper edge of the conveyor belt
and the nozzle on segment 1. The HEIGHTHEADx is
then calculated by subtracting the length of the nozzle
on segment 1 from the measured value. The nozzle
length is defined in the machine data. So
HEIGHTHEADx is a relative not an absolute value.
A value of 0 indicates an error
1312002
1412002
2312002
2412002
SV L GANTRYINFO1
GANTRYINFO2
GANTRYINFO3
GANTRYINFO4
Gantry information for head 1. The data is

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 172 of 236 ©Siemens AG, all rights reserved
VID Class Format Name and Description
automatically reseted when a PCB reaches the
corresponding processing conveyor.
<L
<I2 CompPickedUp>
<I2 CompPlaced>
<I2 CompLeft2Place>
>
CompPickedUp Number of components which
were picked up successfully since
the last PCB reached the center
conveyor
CompPlaced Number of components which
were placed since the last PCB
reached the center conveyor
CompLeft2Place Number of components which
were not placed on the actual
PCB
An empty list indicates an error.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
1312003
1412003
2312003
2412003
SV L PLACEINFO1
PLACEINFO2
PLACEINFO3
PLACEINFO4
Placement information for head x.
<L
L <
<U4 X-position> [1/1000 mm]
<U4 Y-position> [1/1000 mm]
<F8 Angle> [1/100 degrees]
<U1 ForceIndex>
<A ReferenceDesignator>
<A ComponentName>
<U2 PackageFormNumber>
<U1 PlacementResult>
<I4 PlacementVacuum> [mbar]

SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 173 of 236
VID Class Format Name and Description
<I4 Vacuum> [mbar]
<U2 DataValid>
<I4 X-deviation> [1/1000 mm]
<I4 Y-deviation> [1/1000 mm]
<F8 Angle> [1/100 degrees]
<U1 Quality> [0 - 100]
<U4 Length> [1/1000 mm]
<U4 Width> [1/1000 mm]
<L
<I4 Pitch_per_lead_group>
....
<I4 Pitch_per_lead_group>
>
<F8 MaxLeadDev>
<F8 MaxBallDev>
<F8 OrthoDev> [degrees]
<U2 LeadCount>
>
.....
>
<U4 X-position>, <U4 Y-position>, <F8 Angle> and
<I4 Vacuum> are not valid for TwinHead
The first element in this list refers to segment 1, the
second to segment 2 and so on. If a segment was not
in use in the last placement cycle the list for that
segment is left empty
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
1312004
1412004
2312004
2412004
SV L PICKUPINFO1
PICKUPINFO2
PICKUPINFO3
PICKUPINFO4
Pick-up information for head x.
<L
<L
<A ComponentName>
<I2 TrackNumber>