00193786-01 - 第174页

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual Page 174 of 236 ©Siemens AG, all rights reserved VID Class Format Name and Description <U2 FeederType> < I 2 L e v e l > <I2 Division> <U1 Loca…

100%1 / 236
SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 173 of 236
VID Class Format Name and Description
<I4 Vacuum> [mbar]
<U2 DataValid>
<I4 X-deviation> [1/1000 mm]
<I4 Y-deviation> [1/1000 mm]
<F8 Angle> [1/100 degrees]
<U1 Quality> [0 - 100]
<U4 Length> [1/1000 mm]
<U4 Width> [1/1000 mm]
<L
<I4 Pitch_per_lead_group>
....
<I4 Pitch_per_lead_group>
>
<F8 MaxLeadDev>
<F8 MaxBallDev>
<F8 OrthoDev> [degrees]
<U2 LeadCount>
>
.....
>
<U4 X-position>, <U4 Y-position>, <F8 Angle> and
<I4 Vacuum> are not valid for TwinHead
The first element in this list refers to segment 1, the
second to segment 2 and so on. If a segment was not
in use in the last placement cycle the list for that
segment is left empty
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
1312004
1412004
2312004
2412004
SV L PICKUPINFO1
PICKUPINFO2
PICKUPINFO3
PICKUPINFO4
Pick-up information for head x.
<L
<L
<A ComponentName>
<I2 TrackNumber>
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 174 of 236 ©Siemens AG, all rights reserved
VID Class Format Name and Description
<U2 FeederType>
<I2 Level>
<I2 Division>
<U1 Location>
<U1 PickUpResult>
<I4 PickUpVacuum> [mbar]
<I4 Vacuum>
>
....
>
<I4 Vacuum> is not valid for TwinHead
The first element in this list refers to segment 1, the
second to segment 2 and so on. If a segment was not
in use in the last pick up cycle the list for that segment
is left empty.
If the component was picked up from a feeder Level
will contain -1.
In the case that the component was picked up from a
tray in the matrix tray changer TrackNumber will
contain the tower of the MTC(1,2). In this way
PICKIPINFOx has the same format as in previous
versions.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
An empty list indicates an error.
1312005
1412005
2312005
2412005
SV L NOZZLECONF1
NOZZLECONF2
NOZZLECONF3
NOZZLECONF4
Nozzle configuration on head x. Only valid after
reference run.
<L
<L
<U4 NOZZLE_TYPE>
<I4 REAL_NOZZLE_LENGTH> [1/1000
mm]
>
......
>
The nozzle length is measured during the reference
SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 175 of 236
VID Class Format Name and Description
run. It depends on the HEIGHTHEADx value. So
REAL_NOZZLE_LENGTH is not a absolute but a
relative value.
It is calculated by subtracting the measured distance
between the nozzle and the upper edge of the
transport conveyor from the HEIGHTHEADx value.
An empty list indicates an error.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
1312006
1412006
2312006
2412006
SV L VACUUMDATA1
VACUUMDATA2
VACUUMDATA3
VACUUMDATA4
Vacuum measurements from the last reference run on
head x. Valid only after reference run.
<L
<L
<I4 open_nozzle> [mbar]
<I4 closed_nozzle> [mbar]
<I4 cubic_nozzle> [mbar]
<I4 not_cubic_nozzle> [mbar]
<I4 tol_dirty_nozzle> [mbar]
<I4 tol_leaky_nozzle> [mbar]
>
.....
>
<I4 closed_nozzle> is not valid for TwinHead
The first element in this list refers to segment 1, the
second to segment 2, and so on.
tol_dirty_nozzle and tol_leaky_nozzle are currently not
used.
An empty list indicates an error.
For a detailed description of the data item see „4.2
Data Item Dictionary“.
1312007
1412007
2312007
2412007
SV L SEGMENTINFO1
SEGMENTINFO2
SEGMENTINFO3