00193786-01 - 第189页
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual ©Siemens AG, all rights reserved page 189 of 236 8 Collection Events 8.1 Error Messages as Error Events Error Messages are reported to the GEM HO ST as Error Events…

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 188 of 236 ©Siemens AG, all rights reserved
RPTID Name VIDs
37 RefRunHead3 1002001<GEMEVENTTEXT>, 1002022<CLOCK>,
2312001< HEIGHTHEAD3>
38 RefRunHead4 1002001<GEMEVENTTEXT>, 1002022<CLOCK>,
2412001< HEIGHTHEAD4>
39 RefRunVac3 1002001<GEMEVENTTEXT>, 1002022<CLOCK>,
2312006< VACUUMDATA3>
40 RefRunVac4 1002001<GEMEVENTTEXT>, 1002022<CLOCK>,
2412006 <VACUUMDATA4>
41 MTCInfo 1002001<GEMEVENTTEXT>, 1002022<CLOCK>,
812002 <MTCINFO>
42 PickHead3 1002001<GEMEVENTTEXT>, 1002022<CLOCK>,
2312004< PICKUPINFO3>
43 PickHead4 1002001<GEMEVENTTEXT>, 1002022<CLOCK>,
2412004< PICKUPINFO4>
44 Errorinfo 1002001<GEMEVENTTEXT>, 1002022<CLOCK>,
1002069<LASTERROR_CODE>, 1002070
<LASTERRORTEXT>
45 GuiMessage 1002001<GEMEVENTTEXT>,
1002022<CLOCK>,
1122007<GUIMESSAGENUMBER>
46 TraceData 1002001<GEMEVENTTEXT>,
1002022<CLOCK>,
2512001<TRACE_PCB_DATA>,
2512002<TRACE_ALL_COMPONENTS>,
2512003<TRACE_SINGLE_CIRCUIT>
47 SpliceDetect 1002001<GEMEVENTTEXT>,
1002022<CLOCK, 2012047<TABLE_ID>,
2012035<LOCATION>,
2012023<TRACKNUMBER>,
2012024<DIVISION>, 2012025<LEVEL
>
Report numbers 1000 - 1100 are reserved for internal use.

SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 189 of 236
8 Collection Events
8.1 Error Messages as Error Events
Error Messages are reported to the GEM HOST as Error Events (the event name begins
with FM_ ). There are Single Events for each Error Message and a Joint Error
(FM_GENERAL, CEID 1001024) for all Error Messages that is accompanied by the CEID
of the Single Event as the Error Code. The user can use the enable/disable mechanism
to select a display type. Use of the FM_GENERAL is recommended for new HOST
applications.
In contrast to the GEM Interface of SIPLACE S20/S23/F4 machines, the special Error
Events (Event Name : FM_…) feature no predefined report. The General Error Event
FM_GENERAL (CEID 1001024) is made available with a predefined report.
8.2 Description of the Event
Software
CEID Name Description
111001
FM_SC_RECV
Error during RMOS System Call
RECV*
111002
FM_SC_DALOC
Error during RMOS System Call
DALOC*
111003
FM_SC_ALOC
Error during RMOS System Call
ALOC*
111004
FM_SC_LOOK
Error during RMOS System Call
LOOK*
111005
FM_SC_RIO
Error during RMOS System Call
RIO*
111006
FM_DATEN_UNBEK_MELD
Unknown data code in MC1 during
data exchange*
111008
FM_CRUN_MALLOC
Error during RMOS System Call
MALLOC*
111017
FM_SWITCH_DEFAULT
Error in default branch*
111018
FM_SW_FALSCHE_F_NR
MC has received wrong error
number*
111019
FM_PW_SP_ABLAUF_NOK
Error during execution of head
nozzle-check*
111020
FM_OPT_INDEX
Data error in MC: optical centering
indices incorrect*
111055
GEM_UNDEF_FEHLER
error not defined for GEM interface
111056
FM_SW_PIP_OFF
Reading of Nozzle offset not
possible*
111057
FM_SYS_INIT
Initialization of software resources
not correct*
111059
FM_GEM_UNBEK_MELD
Unknown message from SC to GEM
computer*
111064
FM_PDV_DAT_RES
Error upon reserving data for GEM*

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 190 of 236 ©Siemens AG, all rights reserved
111065
FM_PDV_NO_DATA
GEM datum not found*
111066
FM_PDV_UNBEK_FHL
Unknown error number from GEM
process data management*
111073
FM_MAPP_11_MA
MAPP_11.MA file missing or faulty*
111074
FM_MAPP_12_MA
MAPP_12.MA file missing or faulty*
111075
FM_MAPP_21_MA
MAPP_21.MA file missing or faulty*
111076
FM_MAPP_22_MA
MAPP_22.MA file missing or faulty*
111078
FM_CONFIG_MA
KONFIG.MA file missing or faulty*
111079
FM_X_PROG_SPUR
X-pick-up position out of travel
range*
111080
FM_Y_PROG_SPUR
Y-pick-up position out of travel
range*
111081
FM_SONST_SPURLEER
Track empty due to exceeding the
travel range or wrong allocation of
nozzles*
111082
FM_SV_SW_FEHLER
Error in placement sequence
software*
111083
FM_BEST_EBENE
Placement sequence error in PCB
data*
111085
FM_SW_VAK_SCAN_MA
file SCANPARA.MA incorrect or
missing*
111086
FM_SW_VAKUUM_MA
file VAKUUM.MA incorrect or
missing*
111089
FM_HOEH_PIP_ZUVIEL
Unknown nozzle at segment, none
specified in configuration*
111090
FM_BLASDRUCK_ZU_GERING
RV head: Air kiss pressure during
placement too low*
111091
FM_BLASDRUCK_ZU_HOCH
RV head: Air kiss pressure during
placement too high*
111093
FM_MAP_MESSD_FEHLT
MP_MESS.DAT mapping file not
available*
111094
FM_MAP_MESSD_NR_FALSCH
Faulty number in MP_MESS.DAT
mapping file*
111095
FM_MAP_MESSD_INDEX
Bad access to MP_MESS.DAT file*
111096
FM_MAP_DAT_KOMM
Task mapping data:
communications error*
111097
FM_GND_FHL_ART_UNBEK
Unknown error in head basic
function
111098
FM_TSP_LP_OBJEKT
Fatal error while creating PCB
object
111099
FM_IPC_KOMM
Faulty LAN communication (IPC)
111100
FM_SW_VAK_Z_MA
VAK_Z.MA file not available or faulty
111101
FM_GUI_TEXT_MA_ERR_IN_
DYN_LIST
System error (ERR_IN_DYN_LIST)