00193786-01 - 第226页

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual Page 226 of 236 ©Siemens AG, all rights reserved <SEGMENTINFO3> will be resetted. 2010024 PCBreadyProc2Conv1 Placement is finished for the PCB in the conveyor…

100%1 / 236
SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 225 of 236
2010006 RefRunGantry1 Reference run complete for the gantry 1
axis
1
2010007 RefRunGantry2 Reference run complete for the gantry 2
axis
1
2010008 TableDownload Software downloaded to the table and
<SOFTWAREREVTABLE> will be
updated.
23
2010009 SingleCircuitOmit The machine signals that it found a single
circuit to omit (Ink Punkt)
Variables HEADID (VID 1022030),
GANTRYID (2012028) and
GANTRYDROUPID (2012029)
are valid.
1
2010010 TapeCut1 Tape cut at location 1 1
2010011 TapeCut2 Tape cut at location 2 1
2010015 MachineReStarted SIPLACE station is re-booting 1
2010016 PickupError An Pickup-Error has occured and
<SEGMENT>, <COMPONENTNAME>,
<MASCHINESIDE>, <LOCATION>,
<TRACKNUMBER>, <DIVISION>,
<LEVEL>, <GANTRYID>,
<GANTRYGROUPID> and <HEADID>
will be updated
28
2010017 PlaceError An Place-Error has occured and
<SEGMENT>,
<REFERENCEDESIGNATOR>,
<COMPONENTNAME>, <GANTRYID>,
<GANTRYGROUPID>, <HEADID>,
<PACKAGEFORMNUMBER> and
<PLACEERRORDESCRIPTION> will be
updated
29
2010018 RefRunGantry3 Reference run complete for the gantry 3
axis
1
2010019 RefRunGantry4 Reference run complete for the gantry 4
axis
1
2010033 MTCDownload Software downloaded to the MTC and
<SOFTWAREREVMTC> will be updated.
23
2010021 PCBstartProc1Conv1 Start of the placement process for the
PCB in the conveyor 1 processing area 1
<GANTRYINFO1>, <GANTRYINFO4>,
<SEGMENTINFO1 >,
<SEGMENTINFO4>
will be resetted.
1
2010022 PCBreadyProc1Conv1 Placement is finished for the PCB in the
conveyor 1 processing area 1.
1
2010023 PCBstartProc2Conv1 Start of the placement process for the
PCB in the conveyor 1 processing area 2
<GANTRYINFO2>, <GANTRYINFO3>,
<SEGMENTINFO2 >,
1
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 226 of 236 ©Siemens AG, all rights reserved
<SEGMENTINFO3>
will be resetted.
2010024 PCBreadyProc2Conv1 Placement is finished for the PCB in the
conveyor 1 processing area 2.
1
2010025 PCBstartProc1Conv2 Start of the placement process for the
PCB in the conveyor 2 processing area 1
<GANTRYINFO1>, <GANTRYINFO4>,
<SEGMENTINFO1 >,
<SEGMENTINFO4>
will be resetted.
1
2010026 PCBreadyProc1Conv2 Placement is finished for the PCB in the
conveyor 2 processing area 1.
1
2010027 PCBstartProc2Conv2 Start of the placement process for the
PCB in the conveyor 2 processing area 2
<GANTRYINFO2>, <GANTRYINFO3>,
<SEGMENTINFO2 >,
<SEGMENTINFO3>
will be resetted.
1
2010028 PCBreadyProc2Conv2 Placement is finished for the PCB in the
conveyor 2 processing area 2.
1
2010029 PickPlaceStartProc1 The machine is starting to pick up and
place components in Processing1 Area.
1
2010030 PickPlaceStopProc1 The Pick/Place process in Processing 1
Area has been interrupted or is finished.
1
2010031 PickPlaceStartProc2 The machine is starting to pick up and
place components in Processing2 Area.
1
2010032 PickPlaceStopProc2 The Pick/Place process in Processing 2
Area has been interrupted or is finished.
1
2010034 TapeCut3 Tape cut at location 3 1
2010035 TapeCut4 Tape cut at location 4 1
Other Error-Events
CEID Name Description
2211001 FM_ABH_KEIN_BE Component not at nozzle after pick-
up
2211002 FM_BEST_KEIN_BE Component not at nozzle before
placement
2211003 FM_ABH_SPURLEER Track empty, no component during
pick-up
2211004 FM_FM_SPURLEER Flatpack magazine is empty
2211005 FM_MHS_CRASH_GEFAHR Second gantry in travel range
2211006 FM_VAK_DELTA_GRENZE_SP RV: intervals open - closed vacuum
values too low
2211007 FM_VAK_OFFEN_GRENZE_SP RV: vacuum values for open nozzles
SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 227 of 236
CEID Name Description
too high
2211008 FM_VAK_KUBISCH_SP RV: cubic vacuum values faulty
2211009 FM_VAK_NICHT_KUBISCH_SP RV: non-cubic vacuum values faulty
2211010 FM_VAK_FHL_NR_UNBEK_SP RV: unknown vacuum error number
2211011
FM_CAN_MSG_ABWERFEN_SP
RV: Defective motor for rejecting
2211012
FM_TW_SP_PINOLE_GEZOGEN
Caution: Sleeve in extended
position, do not move placement
head!
2211013 FM_VAK_SEGM_UNDICHT_SP Leak in RV-head segment after
placement
2211015 FM_BZ_SCHUETZ_SZ4 Software enable relay defective
2211016 FM_BZ_DRUCKTLUFT Compressed air failure for too long
2211017 FM_BZ_UNBEK_ZUST Status unknown
2211018 FM_BZ_SCHUTZ Cover not correct
2211019 FM_BZ_HALTEPUNKT Break point not defined
2211020 FM_BZ_SCHLUESSEL Unknown key-switch message
2211021 FM_BZ_SENDENBZ Unknown message code to BZ
2211022 FM_BZ_HAUPTSCHUETZ Hardware defect (relay)
2211023 FM_GUI_TEXT_BB_ERR_WAR
TE_ENDE_PORT_KPF_REF
Gantry and head reference run
failed
2211024 FM_GUI_TEXT_BB_ERR_WAR
TE_ENDE_HOEHE_REF
Height reference run failed
2211025 FM_GUI_TEXT_BB_ERR_FAHR
E_POSITION
Unable to move gantry
2211027
FM_GUI_TEXT_TI_FOERD_FOLIE
Error upon cover foil of a tape
feeder
2211028 FM_BETR_DATEN_NOK Error upon producing operating data
for a HOST system
2211029 FM_HEAD_TIMEOUT Timeout during head functions
2211031 FM_NOZZLE_NOK Nozzle cannot be changed, function
not executed
2211039 FM_GEM_SPOOL_FULL Spoolfile is nearly full, machine
stopped (only if safespoolmode is
activ)
2211040 FM_REMOTE_START Remote Start by Gem-Host
2211041 FM_REMOTE_STOP Remote Stop by Gem-Host