00193786-01 - 第229页

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual ©Siemens AG, all rights reserved page 229 of 236 ALID ALCD ALTX Description ON CEID OFF CEID ALID Alarm ID ALCD Alarm Severity Code. The low-order 7-bits of ALCD sp…

100%1 / 236
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 228 of 236 ©Siemens AG, all rights reserved
SIPLACE Placement Head 3
CEID Name Description
2310001 Place3Cycle Placement cycle completed on head 3 and
<PLACEINFO3> , <PLACEINFO3SUB1> will be
updated.
33
2310002 PickUp3Cycle Pick-up cycle completed on 3 and
<PICKUPINFO3> will be updated.
42
2310003 Nozzle3changed <NOZZLECONF3> changed on placement-head 3. 35
2310004 RefRunHead3 Head <HEIGHTHEAD3> reference run complete
on head 3.
37
2310005 NozzleRefRun3 <NOZZLECONF3> length reference run complete
on head 3.
35
2310006 VacRefRun3 <VAKUUMDATAHEAD3> reference run complete
on head 3.
39
SIPLACE Placement Head 4
CEID Name Description
2410001 Place4Cycle Placement cycle completed on head 4 and
<PLACEINFO4>, <PLACEINFO4SUB1> will be
updated.
33
2410002 PickUp4Cycle Pick-up cycle completed on head 4 and
<PICKUPINFO4> will be updated.
43
2410003 Nozzle4changed <NOZZLECONF4> changed on placement-head 4. 36
2410004 RefRunHead4 Head <HEIGHTHEAD4> reference run complete
on head 4.
38
2410005 NozzleRefRun4 <NOZZLECONF4> length reference run complete
on head 4.
36
2410006 VacRefRun4 <VAKUUMDATAHEAD4> reference run complete
on head 4.
40
Traceability (only available if Traceability-Option is installed)
CEID Name Description
2510001 TraceData Traceabilitydata for one PCB 46
2510002 SpliceDetected Splicedetection at a Feeder (only if splicedetction
sensor is installed)
47
2510003 TraceOn Traceability activ 01
2510004 TraceOff Traceability inactiv 01
9 Alarms
There are no alarms defined for SIPLACE
SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 229 of 236
ALID ALCD ALTX Description ON CEID OFF
CEID
ALID Alarm ID
ALCD Alarm Severity Code. The low-order 7-bits of ALCD specifies the severity
code. The high-order bit (bit-8) shows the current alarm state (1=SET,
0=CLEAR).
ALTX Alarm Text. This is the actual string sent the Host in the Alarm Report
(S5F1).
ON CEID This is the Collection Event that is signaled when the alarm state changes
from CLEAR to SET ("going-on").
OFF CEID This is the Collection Event that is signaled when the alarm state changes
from SET to CLEAR ("going-off").
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 230 of 236 ©Siemens AG, all rights reserved
10 Possible Uses of the SIPLACE GEM Interface
10.1 Process Control
You can use the SIPLACE GEM interface to check and continuously improve your
production process. To do so, you must monitor critical process parameters. In the event
there are large deviations from the desired value, you can stop the process and make
corrections.
One example: Pickup reliability
You can monitor the pickup reliability with the event
CEID 2010016 PickupError.
You will obtain vacuum values from the pickup processes from the Event PickUpxCycle.
You will receive summarizing information about pickup reliability relative to the placement
head and the PCB from the variables GANTRYINFOx. With the variables
SEGMENTINFOx you will obtain summarizing information relative to nozzles. This will
enable you to pinpoint, for example, inaccurately adjusted feeders or faulty nozzles.
10.2 Traceability
You can collect all data you require to retrace the use of components on the various
PCBs.
If you store these data, you can still ascertain later, e.g., if there are recall actions, which
PCBs were populated with components from a faulty batch.
You can use the component barcode to acquire the batches used. With a single GEM
event you can ascertain where which components were placed.
Please note that you must have traceability option installed an activated to get traceability
data.
10.2.1 Structure of traceability data
You can use the event CEID 2510001 TraceData with predefined report 46 to get all
traceability data of one PCB.
Variable VID 2512001 TRACE_PCB_DATA gives you basic information about the whole
board.
Variable VID 2512003 TRACE_SINGLE_CIRCUIT gives you information related to single
circuits. If you don't have single circuits you will have only one structure which means the
whole board.
Variable VID 2512002 TRACE_ALL_COMPONENTS gives you information about the
batches used to produce the actual board. This may be a tape or another kind of feeder.
In this version it is not possible to include information from a MTC into your traceability
data. All values beginning with MTC... are zero.
There is a reference number which gives you the relation of a single circuit to the tapes
which where used for the board.