SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual ©Siemens AG, all rights reserved page 57 of 236 3.11 Remote Commands Setup and processing on the SIPLACE machines can be driven by either a local operator or by a H…

100%1 / 236
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 56 of 236 ©Siemens AG, all rights reserved
Purge Spool
The SIPLACE is purging its spool, erasing all
spooled messages.
Transmit Spool
The SIPLACE is transmitting spooled messages
to the Host.
3.10.4 Related Variables
The following table lists the variables (SV's, EC's, or DVVALS) which are relevant to
spooling. For a more complete description of these variables, see "Appendix A --
Variables".
Variable Name VID
MAXSPOOLTRANSMIT 1002037
CONFIGSPOOL 1002045
SPOOLCOUNTACTUAL 1002038
SPOOLCOUNTTOTAL 1002039
OVERWRITESPOOL 1002046
SPOOLFULLTIME 1002040
SPOOLLOADSUBSTATE 1002041
SPOOLSTARTTIME 1002042
SPOOLSTATE 1002043
SPOOLUNLOADSUBSTATE 1002044
MAX_TIME_TO_STOP 1002942
SAFE_SPOOL_MODE 1002943
3.10.5 Related Events
The following lists the collection events (CEIDs) which are relevant to spooling. For a
more complete description of these events, see "Appendix B -- Collection Events" or the
description in this chapter.
Collection Event CEID
GemSpoolingActivated 1000007
GemSpoolingDeactivated 1000008
GemSpoolTransmitFailure 1000009
FM_GEM_SPOOL_FULL 2211039
SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 57 of 236
3.11 Remote Commands
Setup and processing on the SIPLACE machines can be driven by either a local operator
or by a Host computer. This section describes the remote commands available at the
Host.
Much of the behavior of SIPLACE and its acceptance of remote commands is directed by
requirements of the Control State. For a complete description of the Control State,
please see section 3.2, "Control States".
The SIPLACE will accept RemoteStart when the Control State is Remote or RemoteStop
when the ControlState is Remote or Local.. While in the Local state, the Host can not put
the Equipment into Remote, this must be done by an operator at the Equipment.
The Host has the ability to configure whether the Equipment will enter the Remote or
local state as a default upon entering the On-Line state from Off-Line. This is done by
setting The ONLINESUBSTATE Equipment Constant (VID 1002009) to 4 (Local) or 5
(Remote).
Once in the Remote state, the Host has the authority to issue any of these remote
commands and they will not be rejected because of an invalid control state. Commands
may be rejected for other reasons (trying to start a process with no material loaded, etc.).
While in Remote state, the Operator still has the ability to issue commands and change
the control state. If the operator issues a command while in Remote state, the SIPLACE
will send the OPERATORCMDINREMOTESTATE collection event if enabled (CEID
1002056). When the Operator "grabs" control away from the Host by changing the
Control State to local, the SIPLACE will send either the GemControlStateLOCAL (CEID
1000003) or GemEquipmentOFFLINE (CEID 1000005) event to the Host.
3.11.1 S2F41 Commands
The general format for remote commands using the S2F41 message is:
S2F41 [W] * H->E
<L [2]
<A RCMD> * Remote command string
<L
<L [2]
<A CPNAME> * Command Parameter Name
<CPVAL> * Command Parameter Value
>
...
>
> .
The following commands may be sent by the Host to the SIPLACE.
3.11.1.1 START
This command starts processing on the SIPLACE assuming all proper initialization has
taken place and material is present.
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 58 of 236 ©Siemens AG, all rights reserved
A Remote Start could conflict with a Safe_Spool_Stop until spooldata ist purged or
transmitted, , see "chapter 3.10 Spooling".
S2F41 [W]
<L [2]
<A 'START'>
<L>
> .
3.11.1.2 STOP
This command will stop the processing of material at the Equipment. PCB´s currently in
process will be completed, but no new PCB will be loaded.
S2F41 [W]
<L [2]
<A 'STOP'>
<L>
> .