00193786-01 - 第65页
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual ©Siemens AG, all rights reserved page 65 of 236 CompPickedUp Number of components which were picked up successfully per Gantry or Segment since the current PCB reac…

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 64 of 236 ©Siemens AG, all rights reserved
ASER - Alarm serial number
Format: U4
used in: S5F71
ASTAT - Alarm status
Format: Boolean
used in: S5F71, S5F73
CEED - Collection event enable/disable code
Format: B[1]
False = Disable
True = Enable
CEID - Collection event ID
Format: U4
used in: S2F35, S2F37, S6F3, S6F9, S6F11, S6F13, S6F15, S6F16, S6F17, S6F18
CLOCK - Clock YYYYMMDDhhmsscc
Format A[16]
used in: S5F71, S5F73, CLOCK, PICKUPDATARESETPOINT
closed_nozzle - Vacuum value for a nozzle
vacuum value measured with closed nozzle
Format: I4
Units are mbar
used in : VACUUMDATAx
ClusterName - Name of the actual cluster
Format: A
used in : TRACE_PCB_DATA
CMDA - Command acknowledge code
Format: B[1]
0 = completed or done
1 = command does not exist
2 = cannot perform now
>2 = other equipment specific error
3- 63 reserved
used in: S2F22, S2F28
CompLeft2Place Number of components which were not placed on the actual PCB
Format: I2
used in : GANTRYINFOx

SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 65 of 236
CompPickedUp Number of components which were picked up successfully per
Gantry or Segment since the current PCB reached the center
conveyor.
Format: I2
used in : GANTRYINFOx, SEGMENTINFOx
CompPlaced Number of components which were placed per gantry or segment
since the current PCB reached the center conveyor.
Format:I2
used in : GANTRYINFOx, SEGMENTINFOx
CompChanged new tape / componentcontainer was added during placement
Format:U2
used in: TRACE_ALL_COMPONENTS
CompContainerSize amount of components in the container
In this version CompContainerSize is always = 0
Format:U4
used in: TAPE_INFO
CompBarcode(x) - Barcode of a component
Format: A
Used in : TRACE_ALL_COMPONENTS, TAPE_INFO
ComponentName - Name of a component
Format: A
used in: PLACEINFOx, PICKUPINFOx, TRACE_ALL_COMPONENTS
CoplanarityErrors
Not used ( = 0)
This value is part of PICKUPERRORSLOCx to be compliant to previous versions
Format: U2
CPACK - Command Parameter Acknowledge Code
Format: B[1]
1 = Parameter Name does not exist
2 = Illegal value specified for CPVAL
3 = Illegal format specified for CPVAL
4 = PP not in library
>4 = other equipment specific error
4- 63 reserved
used in: S2F22, S2F28
CPNAME - Command Parameter Name
Format: A
used in: S2F41, S2F42
CPVAL - Command Parameter Value

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 66 of 236 ©Siemens AG, all rights reserved
Format:
used in: S2F41
cubic_nozzle - Vacuum value for a nozzle
threshold for cubic components
Format: I4
Units are mbar
used in : VACUUMDATAx
DATAID - Data ID
Format:
used in: S2F33, S2F35, S2F39, S2F49, S6F3, S6F5, S6F9, S6F11, S6F13, S6F13,
S6F16, S6F18
DATALENGTH - Data Length
Format: U4
used in: S2F39, S6F5
DataValid
The fields following the item „DataValid“ represent the result of optical centering. All fields
are not necessarily valid for all package forms. Verify the validity of a field using the
„DataValid“ byte and refer to the corresponding flag for the appropriate field.
If a bit is equal '1' the corresponding field is valid.
Bit 1 X-dev, Y-dev. and angle
Bit 2 Length and Width
Bit 3 lead count
Bit 4 Pitch
Bit 5 Orthogonal deviation
Bit 6 max. lead deviation
Bit 7 max. ball deviation
Example:
Data Valid = 39 (decimal) corresponds to a binary value of 0100111. This means
'X-dev, Y-dev. and angle', 'Length and Width', 'lead count' and 'max. lead deviation'
are valid.
Format: U2
Used in PLACEINFOx, PLACEINFOxSUB1
Division - Division at a feeder or the smallest partition in the tray of a Matrix Tray
Changer
Format: I2
used in: PICKUPINFOx
DRACK - Define Report Acknowledge Code
Format: B[1]
0 = Accept