00193786-01 - 第73页

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual ©Siemens AG, all rights reserved page 73 of 236 MHEAD - Message block header associated with block in error Format: B[16] used in: S9F1, S9F3, S9F5, S9F7, S9F11 MID…

100%1 / 236
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 72 of 236 ©Siemens AG, all rights reserved
LRACK - Limit Report Acknowledge Code
Format: B[1]
0 = Accepted
1 = Denied. Insufficient space
2 = Denied. Invalid format
3 = Denied. At least one CEID link already defined
4 = Denied. At least one CEID does not exist
5 = Denied. At least one RPTID does not exist
>5 = Other errors
6 - 63 reserved
used in: S2F36
LVACK - Variable limit definition acknowledge code
Format: B[1]
1 = Variable does not exist
2 = Variable has no limits capability
3 = Variable repeated in message
4 = Limit value error as desired in LIMITACK
5 - 63 reserved
used in: S2F46
MachineSide - Side of the machine
Format: U1
0 = right side in transport direction
1 = left side in transport direction
MaxBallDev - Maximal ball deviation
MaxBallDev is calculated by the vision system during the optical centering of a package
form. It is calculated over all balls in all ball groups.
Format: F8
Units are 1/1000 mm
used in: PLACEINFOx,
MaxLeadDev - Maximum lead deviation
MaxLeadDev is calculate by the vision system during the optical centering of a package
form. It is calculate over all leads in all lead groups.
Format: F8
Units are 1/1000 mm
used in: PLACEINFOx,
MAX_TIME_TO_STOP - amount of minutes of spooling until a Remote Stop (if
Safe_Spool_Mode is activ)
Format: U4
MDLN - Equipment Model Type
Format: A
used in: S1F2, S1F13, S1F14, S1F65, S1F66
SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 73 of 236
MHEAD - Message block header associated with block in error
Format: B[16]
used in: S9F1, S9F3, S9F5, S9F7, S9F11
MID - Lot ID
Format: A[16]
used in S2F27
Tower (Number) - A MTC has 2 Towers.
Values 1,2
Used in MTCInfo, TOWER_ID
MTC_number - Number to identify a MTC
This number corresponds to the value of LOCATION
Format: U1
Values 1,2,3,4
Used in MTCInfo
not_cubic_nozzle - Vacuum value for a nozzle
vacuum threshold for melfs, etc.
Format: I4
Units are mbar
used in : VACUUMDATAx
NOZZLE_TYPE: - Number of a nozzle
For a detailed description see „SIPLACE Placement Stations - Data Interface: Chapter
Nozzle Types“.
Format: U4
used in : NOZZLECONFx, NOZZLERETURN,
ONLACK Acknowledge for code for ON-LINE request
Format: B[1]
0 = Accepted
1 = Denied
2 = Equipment already ON-LINE
3 - 63 reserved
used in S1F18
open_nozzle - Vacuum value for a nozzle
vacuum value measured with an open nozzle
Format: I4
Units are mbar
used in : VACUUMDATAx
OpticalErrors - Number of optical errors since last download of a process program
Format: U2
used in: PICKUPERRORSLOCx
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 74 of 236 ©Siemens AG, all rights reserved
OrthoDev - Orthogonal deviation
Format: F8
Units are 1/100 degree
used in : PLACEINFOx
PackageFormNumber - Identifier for a package form
Format: U2
see chapter 9 in the SIPLACE Data Interface ( <pack_form_no>).
used in: PLACEINFOx
PCBBarcode Barcode of the current PCB
Format: A
used in : TRACE_PCB_DATA
PickErrors - Number of pickup errors per segment since the current PCB reached the
corresponding processing conveyor.
Format:I2
used in : SEGMENTINFOx
PickUpErrors - Number of pick-up errors since last download of a process program
Format: U2
used in: PICKUPERRORSLOCx
PickUpResult - Result of the pick up action
Format : U1
0 NOK (default value, should not appear)
1 OK
2 NOK
3 REUSED (picked up in a previous cycle)
used in : PLACEINFOx
PickUpVaccum - Vaccum measured at pick-up position.
PickUpVacuum is measured in the pick up circuit after a component is picked up
Format : I4
Units are mbar
used in : PICKUPINFOx
Pitch_per_lead_group - Distance between leads.
During the optical centering of a package the vision system calculate the average
distance between the leads within a lead group.
Format: I4
used in : PLACEINFOx
PLACEERRORDESCRIPTION – Description of an placement error.