00193786-01 - 第77页
SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual ©Siemens AG, all rights reserved page 77 of 236 1 = Denied, busy try later 2 = Denied, spooled data does not exist 3 - 63 reserved used in: S2F24 RSDC Request Spool…

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 76 of 236 ©Siemens AG, all rights reserved
Format: U4
used in: S2F33, S2F35, S6F3, S6F9, S6F11, S6F13, S5F16, S6F18, S6F19, S6F21
ProdTimeStart Time of production start
Format: A
used in : TRACE_PCB_DATA
ProdTimeEnd Time of production end
Format: A
used in : TRACE_PCB_DATA
Quality - Measurement result of a package form or a fiducial
Quality ranges between 0 and 100. The higher the value, the better the fiducial was
recognized.
Format: U1
used in: PLACEINFOx, FIDUCIALDATA
RCMD - Remote Command
Format: A
used in: SsF21, S2F41
RealNozzleLength - measured nozzle length
The nozzle length is measured during the reference run. It depends on the
HEIGHTHEAD value. So REAL_NOZZLE_LENGTH is not a absolute but a relative value.
It is calculated by subtracting the measured difference between the nozzle and the upper
edge of the conveyor belt from the HEIGHTHEAD value.
Format: I4
Units are 1/1000 mm
Reference - Referencenumber of a componentbatch
One reference used in TRACE_SINGLE_CIRCUIT points to one component in
TRACE_ALL_COMPONENTS.
Format: U4
ReferenceDesignator - Identifier for a placement position
Format: A
see chapter 5.4 in the SIPLACE Data Interface ( <position_name> in
<placemant_pos_record>).
used in: PLACEINFOx
REPGSZ - Reporting group size
Format: U4
used in: S2F23
RSDA - Request Spool Data Acknowledge
Format: B[1]
0 = OK

SIPLACE GEM SW Version GEM 505.01
HOST Interface Manual
©Siemens AG, all rights reserved page 77 of 236
1 = Denied, busy try later
2 = Denied, spooled data does not exist
3 - 63 reserved
used in: S2F24
RSDC Request Spool Data Code
Format: B[1]
0 = Transmit Spooled Massages
1 = Purge Spooled Messages
2 - 63 reserved
SAFE_SPOOL_MODE (EC)
0 = SAFE_SPOOL_MODE is not activ (no SafeSpool-Stop)
1 = SAFE_SPOOL_MODE is activ, SafeSpool-Stop after MAX_TIME_TO_STOP Minutes
of spooling
SEGMENT – Number of the segment to pick up or place a component.
Format: U1
Setup Name of the current Setup
Format: A
used in : TRACE_PCB_DATA
SHEAD - Stored header related to the transaction timer
Format: B[10]
used in: S9F9
SingleCircuitName - Name of a singlecircuit on a pcb
Format: A
used in: TRACE_SINGLE_CIRCUIT
SMPLN - Sample number
Format : U4
used in: S6F1
SOFTREV - Software revision code
Format: A[6]
used in: S1F2, S1F13, S1F14, S1F65, S1F66
STIME - Sample time
Format: A[16]
used in: S6F1
STRACK - Spool Stream Acknowledge
Format: B[1]
1 = Spooling not allowed for stream
2 = Stream unknown
3 = Unknown function specified for this stream

SIPLACE GEM SW Version GEM 505.01 HOST Interface Manual
Page 78 of 236 ©Siemens AG, all rights reserved
4 = Secondary function specified for this stream
used in: S6F44
STRID - Stream ID
Format: U1
used in: S2F43, S2F44
SVID - Status Variable ID
Format
used in: S2F23
SVNAME - Status variable name
Format: A
used in: S1F12
Table Barcode - Barcode of a table
Format: A
used in: Table _ID
TEXT - A single line of characters
Format: A[160]
used in: S10F1, S10F3, S10F5, S10F9
TIAACK - Equipment Acknowledge Code
Format: B[1]
0 = everything correct
1 = too many SVIDs
2 = no more traces allowed
3 = invalid period
4 - 63 reserved
used in; S2F24
TIACK - Time Acknowledge Code
Format: B[1]
0 = OK
1 = Error, not done
2 - 63 reserved
used in; S2F32
TID - Terminal ID
Format: B[1]
0 = single or main terminal
>0 = additional terminals on same equipment
used in: S10F1, S10F3, S10F5
TOTSMP - Total sample to be made
Format: U4
used in: S2F23
TrackNumber - Number of a track