Error ID Item Description
420203 Input Cnvr. P.C.B. Overtime P.C.B. on X/Y table chute was not able to move to its outlet.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
420301 Output Cnvr. Overtime P.C.B. to output machine was not transferred.
420302 Output Cnvr. Overtime P.C.B. on output cnvr. was not able to move to its outlet.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
420401 Input Buffer Cnvr. Inp. machine send sig. turned off before P.C.B. reached input
P.C.B. Detection cnvr.
420402 Input Buffer Cnvr. P.C.B.
,
s were at inlet and outlet of input buffer cnvr.
P.C.B. Detection
(Cause 1) The P.C.B. transfer signal from the input machine was turned off before the P.C.B.
was detected by the P.C.B. detection photosensor at the input conveyor outlet side.
There are two P.C.B.’s on the input conveyor.
(Remedy 1) Adjust the position of the P.C.B. detection photosensor (outlet).
The P.C.B. detection photosensor (outlet) is defective and required to be replaced
with a new one.
420501 Input Cnvr. P.C.B. Detection The sensor position is illegal setting.
420502 Input Cnvr. P.C.B. Detection P.C.B.
,
s were at inlet and outlet of input cnvr.
420503 Input Cnvr. P.C.B. Detection P.C.B. on inp. cnvr. was not able to move to its transfer action.
(Cause 1) The P.C.B. was carried back to the P.C.B. transfer claw during automatic operation.
Or, the P.C.B. is shifted out of the coverage of the P.C.B. detection photosensor.
The P.C.B. detection photosensor is attached to a wrong position.
The X value of “P.C.B. SIZE” has exceeded the range of setting.
(Remedy 1) Press the [RETURN] button to cancel the error display and zero the P.C.B. transfer.
Adjust the position of the P.C.B. detection photosensor.
Set the correct X value for “P.C.B. SIZE”.
0110-003 2-104 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
420601 Output Cnvr. P.C.B. Detection Out. machine work req. sig. turned off before P.C.B. trns.act
completed.
420602 Output Cnvr. P.C.B. Detection P.C.B. on output cnvr. was not able to move to its outlet.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
430101 Nozzle Change Nozzle change action error.(DD-head camfree position)
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
430201 NOZZLE POSITION The nozzle dropped.; BPX29
(Cause 1) The optical beam was not set in the “E/R” or the “E/NR” condition due to dirt on the
sensor. (E/R: Light Emitted and Received, E/NR: Light Emitted and Not Received)
The sensor may be defective.
(Cause 2) The nozzle is not attached correctly.
(Remedy 1) Press the [RETURN] button to cancel the error display and check that no dirt
adheres to the sensor.
(Remedy 2) Attach the nozzle correctly.
430202 NOZZLE POSITION THE SELECTED NOZZLE WAS ERRONEOUSLY POSI-
TIONED.; BPH15
(Cause 1) The selected nozzle moved down, passing over the low level at Station #10.
Self-Diagnostics Error Message.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0110-003 2-105 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
430203 NOZZLE POSITION THE SELECTED NOZZLE LEVEL WAS NOT AT HIGH PO-
SITION.; BPH16
430204 NOZZLE POSITION THE SELECTED NOZZLE LEVEL WAS NOT AT LOW
POSION.; BPH16
(Cause 1) The optical beam was not set in the “E/R” or the “E/NR” condition due to dirt on the
sensor. (E/R: Light Emitted and Received, E/NR: Light Emitted and Not Received).
The sensor may be defective.
(Remedy 1) Confirm that no dirt adheres to the sensor. Or, it may be necessary to replace the
sensor with a new one because it may be defective.
Before replacing the sensor, contact our service personnel for some advice.
430205 NOZZLE POSITION THE SELECTED NOZZLE LEVEL POSITION SENSOR WAS
NOT ACTIVATED.; BPH15, 16
(Cause 1) The optical beam was not set in the “E/R” or the “E/NR” condition due to dirt on the
sensor. (E/R: Light Emitted and Received, E/NR: Light Emitted and Not Received).
The sensor may be defective.
(Remedy 1) Press the [RETURN] button to cancel the error display and check that no dirt
adheres to the sensor.
430206 NOZZLE POSITION THE UNSELECTED NOZZLE WAS ERRONEOUSLY POSI-
TIONED.; BPH17, BPH18
(Cause 1) The optical beam was not set in the “E/R” or the “E/NR” condition due to dirt on the
sensor. (E/R: Light Emitted and Received, E/NR: Light Emitted and Not Received).
The sensor may be defective.
(Cause 2) This error occurs when the nozzle almost comes off at Station #8 and touches the
component discharge plate.
(This error occurs during automatic or manual operation.)
(Remedy 1) Confirm that no dirt adheres to the sensor. Or, it may be necessary to replace the
sensor with a new one because it may be defective.
Before replacing the sensor, contact our service personnel for some advice.
(Remedy 2) Check the head at Station #8. Subsequently, perform the reverse rotation opera-
tion to move the head back toward the front side of the machine. Then, insert the
nozzle deep inside.