3.3 Error IDs and Remedial Procedures
0210-001 2-160-9 AFO01ETRP
Error ID ltem Description
801501 Feeder Index Position Production operation was interrupted in the middle of feeder
index operation. Please check a position.
801502 Feeder Index Position The feeder carriage was returned to the home position in the
middle of feeder index operation. Please check a feeder index
position.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801601 Product Restart Restart production with semi-auto(after specified step) mode.
801602 Product Restart Restart production with warm start mode.
801603 Product Restart Restart production with warm start mode after EMER stop.
Machine will stop after placement complete. Please confirm
PCB afterward.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801701 Teach Nozzle Bypass Nozzle Down Error.(L)
801702 Teach Nozzle Bypass Nozzle Down Error.(H)
801703 Teach Nozzle Bypass Recognition Teach Error.
801704 Teach Nozzle Bypass Teach Error Data.
801705 Teach Nozzle Bypass Lighting Check.
801706 Teach Nozzle Bypass Nozzle Level.
801707 Teach Nozzle Bypass Nozzle Drop
801708 Teach Nozzle Bypass Dummy Nozzle.
801709 Teach Nozzle Bypass Manual Bypass.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures
0210-001 2-160-10 AFO01ETRP
Error ID ltem Description
80170a Teach Nozzle Bypass Nozzle Change Error.(Cam lock action)
80170b Teach Nozzle Bypass Nozzle Change Error.(Cam Free action)
80170c Teach Nozzle Bypass Cam Origin Error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801801 Teach Head Bypass Communication Error.
801802 Teach Head Bypass Head Origin Error.
801803 Teach Head Bypass Overtime Head Origin Return.
801804 Teach Head Bypass Unselected Nozzle Drop.
801805 Teach Head Bypass Dummy Nozzle.
801806 Teach Head Bypass Manual Bypass.
801807 Teach Head Bypass Alarm Error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801901 Nozzle Adjustment Nozzle up&down action is not available.
801902 Nozzle Adjustment Communication error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
Error ID ltem Description
801a01 Warning Operation Product started by RUN MODE “PASS”Operation.
801a02 Warning Operation The P.C.B. before component placing was conveyed from X/Y
table.
801a03 Warning Operation The P.C.B. in the middle of component placing was conveyed
from X/Y table.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801b01 Lightning Surge Warning Lightning Surge Protector works; Q204.
801b02 Lightning Surge Warning Lightning Surge Protector works; Q204. Running continue.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801c01 Information This placement step was detected outside of the possible
range. This step is auto skip running.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
801c02 Information Feeder carriage has been paused to avoid clash with missing
component. Please collect component before operating the
feeder carriage.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Before activating the feeder axis, shut off the power and remove the mispicked
component.
Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
0307-002 2-160-11 AFO01ETRP