Recognition Error ID Item Description 0139310001 “Component Library Polarity Component shape” ---- Not Supported! (Cause) The data is not supported. (Remedy) Set the supported data. 013931 1001 Error in “Component Librar…

Recognition Error ID Item Description
0139214021 “Polarity Inspection Position” Out of “Mold Size” ----
0139214022 “Elctd # of Rows or # of Cols” in "Elctd Group 1" ----
is Not Sufficient
0139214023 “Elctd # of Rows or # of Cols” in "Elctd Group 2" ----
is Not Sufficient
0139214024 “Elctd # of Rows or # of Cols” in "Elctd Group 3" ----
is Not Sufficient
0139214025 “Elctd # of Rows or # of Cols” in "Elctd Group 4" ----
is Not Sufficient
0139214026 “Elctd # of Rows or # of Cols” in "Elctd Group 5" ----
is Not Sufficient
0139214027 “Elctd # of Rows or # of Cols” in "Elctd Group 6" ----
is Not Sufficient
0139214028 Electrode Position Superposed in Different ----
Electrode Group!
0139221001 Failed in Automatic Selection of Algorithm for ----
Lealess Components.
0139221002 Failed in Automatic Selection of Algorithm for ----
Leaded Components.
0139221003 Failed in Automatic Selection of Algorithm for ----
Area Array.
0139221004 Failed in Automatic Selection of Algorithm for ----
Cylindrical Components.
0139221005 Failed in Automatic Selection of Algorithm for ----
Square Components.
0139221006 Failed in Automatic Selection of Algorithm for ----
Deformed Components.
0139221007 Failed in Automatic Selection of Algorithm for ----
ICs.
0139221008 Failed in Automatic Selection of Algorithm for ----
Connectors.
0139221009 Failed in Automatic Selection of Algorithm for ----
Leaded Components.
0139221010 Failed in Automatic Selection of Algorithm for ----
BGA Components.
0139300005 Error in “Component Library Pickup Pos ----
Correction X or Y” Data.
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0210-004 2-170 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures

Recognition Error ID Item Description
0139310001 “Component Library Polarity Component shape” ----
Not Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0139311001 Error in “Component Library Mold Size X or Y” ----
Data
0139311002 Error in “Component Library Mold Size T or t or ----
Ut” Data
0139311003 Error in “Component Library Outward Length” ----
Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0139312001 “Component Library Component type” Not ----
Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0139312002 Error in “Component Library Elctd Size” Data ----
0139312112 Error in “Component Library Corner Dim X or Y” ----
Data
0139312212 Error in “Component Library Edge Detection ----
Posn” Data
0139312301 Error in “Component Library Number of Linear ----
Edges” Data
0139312311 Error in “Component Library Linear Start ----
Position” Data
0139312312 Error in “Component Library Linear Direction” ----
Data
0139312313 Error in “Component Library Linear Width ----
(Length)” Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0210-004 2-171 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures

Recognition Error ID Item Description
0139313002 “Component Library Lead Type” Not Supported! ----
0139313111 “Component Library Polarity Lead Shape” Not ----
Supported!
(Cause) The data is not supported.
(Remedy) Set the supported data.
0139313112 Error in “Component Library Lead Width” Data ----
0139313113 Error in “Component Library Lead Length” Data ----
0139313114 Error in “Component Library Lead Full Length” ----
Data
0139313212 Error in “Component Library Lead Center ----
Posn(Latl)Det” Data
0139313213 Error in “Component Library Lead Top ----
Posn(Long)Det” Data
0139313214 Error in “Component Library Lead Direction” ----
Data
0139313215 Error in “Component Library Lead # of Leads” ----
Data
0139313216 Error in “Component Library Lead Pitch” Data ----
0139313217 Error in “Component Library Lead Missing Lead ----
Start” Data
0139313218 Error in “Component Library Lead # of Missing ----
Leads” Data
(Cause) Wrong parameters are set.
(Remedy) Set correct parameters.
0210-004 2-172 AFO01ETRP
4.3 Recognition Error IDs and Remedial Procedures