(10) After the lubrication is all completed (Supply Hole Position: 3, Crnt Oil Supply No. (#1 - #24): 24), press the [Next] button. The following sheet appears. Fig. 4A84-10 (1 1) Press the [ON] button entitled "MOV…

1.4 Maintenance Method
0307-005 1-71 AFO01ETRP
(8) Press the [ON] button entitled "MOVE". In 2 seconds, press the
[ENABLE] button on the operation panel.
The grease nipple of No. 2 on Feeder Carriage #2 moves to the
grease supply position and the following sheet appears. Inject
grease from the nipple.
Fig. 4A84-9
"Oil Supply" Tab Sheet (Second Grease Supply Position)
(9) Apply grease to 24 spots (the front and rear sides of the machine)
in the same way.
Whenever you notice that you forgot to supply grease to a spot,
press the [Back] button (*1) and the [ON] button (entitled
"MOVE"). In 2 seconds, press the [ENABLE] button on the opera-
tion panel. The previous grease supply position is selected.
*1

(10) After the lubrication is all completed (Supply Hole Position: 3,
Crnt Oil Supply No. (#1 - #24): 24), press the [Next] button. The
following sheet appears.
Fig. 4A84-10
(11) Press the [ON] button entitled "MOVE". In 2 seconds, press the
[ENABLE] button on the operation panel. The aging of the feeder
carriage section starts.
(12) After the aging is completed, the following tab sheet appears.
Fig. 4A84-11
1.4 Maintenance Method
0307-005 1-72 AFO01ETRP

1.4 Maintenance Method
0307-006 1-73 AFO01ETRP
(13) Press the [ON] button entitled "MOVE". In 2 seconds, press the
[ENABLE] button on the operation panel. The feeder carriages 3
and 4 move toward the F1 origin and the following sheet appears.
Fig. 4A84-12
(14) Press the [EMERGENCY STOP] switch on the operation panel.
An "ERROR" window opens and the machine stops in an emer-
gency condition.
(15) Open the feeder carriage covers on the F4 side and clean the lin-
ear scales on the F4 side with a cotton swab soaked in alcohol
(absolute ethanol).
Never use any organic compounds other than alcohol.
(16) Close all feeder carriage covers.
Turn the [EMERGENCY STOP] switch clockwise to cancel the
emergency stop condition.
Press the [RETURN] button in the "ERROR" window.
(17) Hold down the [POWER ON] button on the operation panel for