Installation_Manual_SIPLACE_Explorer_2.4_EN - 第9页

Installation and Configuration Guide SIPLACE Explorer 1 Introduction Edition 08/2008 EN 1.3 Additional Remarks 9 –S W 4 0 7 –S W 4 0 8 – SW 101 for the CS and CF machine The following version is supported but if problems…

100%1 / 116
1 Introduction Installation and Configuration Guide SIPLACE Explorer
1.2 System Requirements Edition 08/2008 EN
8
MS XML Core Services 6.0,
included on the Support Media DVD
MS Excel (required for the PC on which Factory Reporting is to be installed) - one of the fol-
lowing versions:
MS Excel 2003
MS Excel 2007
MS Internet Explorer - one of the following versions:
MS Internet Explorer 6.0 SP1, included on the Support Media DVD
MS Internet Explorer 7.0, installed with the Windows Vista installation
Acrobat Reader 7.0
included on the Support Media DVD
1.2.3 Supported Data Sources
SIPLACE Explorer V2.4 supports data from the following SIPLACE products: 1
OIS 5.2, SIS 5.2, SIPLACE Pro 5.2
OIS 5.1, SIS 5.1, SIPLACE Pro 5.1
OIS 5.0, SIS 5.0, SIPLACE Pro 5.0
OIS 4.1, SIS 4.1, SIPLACE Pro 4.1
OIS 4.0, SIS 4.0, SIPLACE Pro 4.0
OIS 3.1, SIS 3.1, SIPLACE Pro 3.2
The following versions are supported but if problems should occur, you will need to update these
versions to those shown above. 1
OIS2.4 SP1, SIS 1.2 SP1, SIPLACE Pro 2.1 SP2
SIPLACE Explorer V2.4 supports data from the following station software versions: 1
SW 701
SW 605
SW 604
SW 603
SW 602
SW 601
SW 505
Installation and Configuration Guide SIPLACE Explorer 1 Introduction
Edition 08/2008 EN 1.3 Additional Remarks
9
–SW 407
–SW 408
SW 101 for the CS and CF machine
The following version is supported but if problems should occur, you will need to update it to the
version shown above. 1
SW 503.04 SP 2: This version is only suitable if an update to SW 505.xx is not possible due to
hardware restrictions.
1.3 Additional Remarks
SIPLACE Explorer Version 2.4 has the following restrictions: 1
Restriction due to NPI mode
SIPLACE Explorer V2.4 is unable to use data from SIS for boards which are marked as "SA"
(stand-alone). This means that the following information is not available for boards marked with
"SA":
Component name
Component shape
Feeder type
The following SMA pages show limited data due to the "Stand-alone" mode: 1
Pickup Reliability
Pickup Summary
Reject Rate
Transition Log
Factory Layout:
A SIPLACE Explorer host (the computer on which SIPLACE Explorer "Runtime Environment"
is installed) can monitor five production lines with up to 20 stations.
Single Line Layout
A SIPLACE Explorer host (the computer on which SIPLACE Explorer "Runtime Environment"
is installed) can monitor one production line with up to 7 stations.
For performance reasons, we recommend that you do not generate reports for all websites and
report types at once. Try to run the report generation at a time when there is no production op-
eration e.g. at the weekend.
1 Introduction Installation and Configuration Guide SIPLACE Explorer
1.3 Additional Remarks Edition 08/2008 EN
10
From SIPLACE Explorer Version 2.0 SP1, the station GEM interface will no longer be sup-
ported i.e. data can not be recorded via the GEM interface with SIPLACE Explorer Version 2.2
or higher. If you need support for the GEM interface, please contact the SIPLACE Hotline.
The system time on the connected machines and that belonging to the SIPLACE Explorer must
be synchronized. SIPLACE machines require the installation of TimeSync, which is included
on the Support Media DVD provided with the delivery.
There is a special OIS status module realized in SIPLACE OIS. This OIS status module is
shown in the SIPLACE Explorer status module which matches the SEMI E10 status module.
This may lead to deviations in the states and status times shown between OIS and SIPLACE
Explorer. A direct comparison is therefore not possible.
The following restriction applies to platform I (S20, S23, F4, F5, F5HM) stations with dual con-
veyors:
The page Production Summary will display Unknown in the Current Recipe List table for
the 2nd conveyor lane. 1
Reason:
Platform I stations are unable to produce different recipes, even with dual conveyors. There-
fore, only one recipe will be loaded for the SIPLACE line. This recipe will then only be assigned
to conveyor lane I by SIPLACE Explorer. 1
When using the conveyor type "dual conveyor", the board counting function is subject to limi-
tations. It only records boards for conveyor lane 1. Boards produced on conveyor lane 2 are
not recorded. SIPLACE Explorer and OIS only show the boards for conveyor lane 1. The com-
ponents placed on the boards on conveyor lane 2 are assigned to the boards recorded for lane
1. This means that the number of consumed components shown is correct. This restriction ap-
plies to the following software versions: 407, 408, 502, 503, 504, 505.01, 505.02. The restric-
tion ceases to apply for version 505.03 onwards.
If partially placed boards are removed from the SIPLACE machine, without specifying this ter-
mination in the station software and removing them via the output conveyor, these boards will
not be recorded by the OIS and SIPLACE Explorer systems. In this case, the station software
is not able to generate the data set needed to record the boards. This restriction applies to all
available versions of the station software. If you need to terminate board placement, always
proceed as follows:
Terminate the board at the station software interface.
Remove the board from the output conveyor of the station and not by opening the hood and
taking it directly out of the placement area.
The following restrictions apply to the SMA pages listed below, if no boards are placed at the
last station in the production line: