6 Converting the power supply on the MTC Assemb ly Instructions, Converting the Power Supply 6.4 Converting the power supply from 3 x 400 VAC to 3 x 208 VAC 12/2013 Edition 218 6 Fig. 6 - 3 MTC2 - terminal panel X01, cir…

100%1 / 282
Assembly Instructions, Converting the Power Supply 6 Converting the power supply on the MTC
12/2013 Edition 6.4 Converting the power supply from 3 x 400 VAC to 3 x 208 VAC
217
On terminal block X01, plug in six transverse jumpers between feed-through terminals 1-2, 3-
4, 5-6, 7-8, 9-10 and 11-12 (BR see Fig. 6 - 2
).
Leave the tripping current setting unchanged at 3.5 A on motor contactor Q01.
6
Fig. 6 - 2 MTC electronic panel - jumper set for 3 x 208 VAC
JMPJumper, 6 x 6
Q01 Motor contactor 6
X01 Terminal block 6
JMP (3 x 208 VAC) 6
6 Converting the power supply on the MTC Assembly Instructions, Converting the Power Supply
6.4 Converting the power supply from 3 x 400 VAC to 3 x 208 VAC 12/2013 Edition
218
6
Fig. 6 - 3 MTC2 - terminal panel X01, circuit diagram 3 x 208 VAC
1V1
1 2 3
2U1
2V1
2W1
4x2.5mm² CSA
1W1
1U1
3.7 kVA /50-60Hz
Oilflex 190
-W003
Transformer T1
3 x 208 VAC / 3 x 400 VAC
3 x 208 VAC / 120 VAC
L1
L2
50Hz / 60 Hz
L3
PE
X01 terminal block
5x2.5mm² CSA
1 2 3 4
Oilflex 190
-W004
PE
L3.1
L1.1
L2.1
C
A A
JMPJMP JMPJMP JMPJMPJMP: 3 x 208 VAC
N
Assembly Instructions, Converting the Power Supply 6 Converting the power supply on the MTC
12/2013 Edition 6.4 Converting the power supply from 3 x 400 VAC to 3 x 208 VAC
219
6.4.2 Conversion work on the T1 transformer for the component table
6.4.2.1 Converting transformer T1 from 230 VAC to 120 VAC
Remove the tape roll container and the waste container.
Release the screws for the MTC cover on the component table side.
Lift off the cover.
6
Fig. 6 - 4 Position of transformer T1 for the component table
6