Assembly Instructions, Converting the Power Supp ly 7 Conv erting the power supply on the HS-60 / D4 / D1/D2 machine 12/2013 Edition 7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC 247 7.6.3 Removing the …

7 Converting the power supply on the HS-60 / D4 / D1/D2 machine Assembly Instructions, Converting the Power Supply
7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC 12/2013 Edition
246
7.6.2.2 Inserting the motor protection trip block
Check the type of motor protection trip block before you insert it. The type depends on the op-
erating voltage.
Tab. 7 - 4 Motor protection trip block for 3x380 VAC, 3x400 VAC, 3x415 VAC
7
Check the overcurrent and short-circuit current trip threshold settings.
Adjustment of the Motor protection trip block at 230/400V 7
Tab. 7 - 5 Overcurrent and short-circuit trip threshold
Fig. 7 - 17 Checking the overcurrent and short-circuit current trip thresholds
Insert the motor protection trip block (3).
Push the yellow locking tab (4) down.
Close the gray protective flap (5).
Turn the rotary switch (6) clockwise as far as the stop.
Main power voltages Type
3x380 V~ ± 5% ZM-16-PKZ2
3x400 V~ ± 5% ZM-16-PKZ2
3x415 V~ ± 5% ZM-16-PKZ2
Motor protection
trip block
Yellow dial (1) for setting
the overcurrent trip
threshold
Red dial (2) for setting the
short-circuit current trip
threshold
HS-60 / D4 ZM-16-PKZ2 10 A 190 A
D1 / D2 ZM-16-PKZ2 10 A 130 A
Check the overcurrent trip
threshold (yellow dial (1))
Check the short-circuit cur-
rent trip threshold
(red dial (2))

Assembly Instructions, Converting the Power Supply 7 Converting the power supply on the HS-60 / D4 / D1/D2 machine
12/2013 Edition 7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC
247
7.6.3 Removing the socket guard from the socket with earthing contact
Remove the Teddy socket guard, series 6310, from the socket with earthing contact using the
corresponding key.
7
7
Socket guard
with key
Socket

7 Converting the power supply on the HS-60 / D4 / D1/D2 machine Assembly Instructions, Converting the Power Supply
7.6 Converting the power supply from 3 x 208 VAC to 3 x 400 VAC 12/2013 Edition
248
7.6.4 Replacing the main power cable
CAUTION
The electrical cables to each individual placement machine must be clearly identified and easy to
allocate without doubt. The regulations of the country in which the machine is operated apply.
The main power cable is connected to the U, V, W, N and PE terminals on terminal strip X1 (see
item X1 in Fig 7 - 12
, page 243).
Detach the wires of the main power cable from the U, V, W, N and PE terminals.
Detach the cable clamp from the cable holder.
Pull the cable out of the cable holder.
Push the main power cable (6 mm²) through the cable holder as far as the terminals on X1.
PLEASE NOTE: 7
Make sure that the cable bending radius is sufficient to prevent the wires being bent. 7
Connect the main power cable to the terminals on X1:
Wire 1 to U on X1,
Wire 2 to V on X1,
Wire 3 to W on X1,
Wire 4 to N on X1 and
Wire YEGN to PE on X1.
(See circuit diagram 00119185-050101LD4, sheet 1, page 254
)
Tighten the cable clamp.