X3_X4_Series machine - 第26页

1 Introduction User manual SIPLACE X-S eries 1.9 Abbreviations Software Version SR. 601.xx 11/2005 US Edition 26 1.9 Abbreviations 1 C&P Colle ct&P lace C&P12 Collect &Place head with 12 segm ents C&P…

100%1 / 464
User manual SIPLACE X-Series 1 Introduction
Software Version SR.601.xx 11/2005 US Edition 1.7 EU Declaration of Conformity
25
1.7 EU Declaration of Conformity
The product/device described below 1
Product: Placement machine
Type: SIPLACE X2 SIPLACE X3 SIPLACE X4
Item no.: 00119700 00119750 00119780 1
manufactured by
SIEMENS AG, Automation and Drives
Electronics Assembly Systems
Rupert-Mayer-Str. 44
D-81359 Munich 1
conforms to the relevant provisions of:
Directive 98/37/EC of the European Parliament and of the Council of June 22, 1998 on
the approximation of the laws of the Member States relating to machinery
Council Directive 89/336/EEC of May 3, 1989 on the approximation of the laws of the
Member States relating to electromagnetic compatibility
The product(s) identified above comply with the requirements of the above EU directive by meet-
ing the following standards: 1
EN 294, EN 349, EN 418, EN 811, EN 1050, EN ISO 12100-1, EN ISO 12100-2, EN 60204-
1, EN 60825-1, EN 61000-3-2/3, EN 61000-4-2/3/4/5/6/8, BGV A1
1
, BGV A2
1
1
1.8 Revision index
1
1
1.8.1 Revisions since 11/2005 edition
1
1. National specifications
This declaration certifies the compliance with the indicated directives but implies no warranty of properties.
The safety instructions of the accompanying product documentation shall be observed.
Manual Software version Edition
First edition User manual 6.01 04/2005 US
Revision User manual 6.01 08/2005 US
Revision User manual 6.01 11/2005 US
New or modified Chapter / Section
Manual removal of tantalum capacitors
by the operator
that have not been picked up
6.6.1
1 Introduction User manual SIPLACE X-Series
1.9 Abbreviations Software Version SR.601.xx 11/2005 US Edition
26
1.9 Abbreviations
1
C&P Collect&Place
C&P12 Collect&Place head with 12 segments
C&P20 Collect&Place head with 20 segments
C&P6 Collect&Place head with 6 segments
CO Component
DC Dual conveyor
DCA Direct chip attach
EDIF Energy and data interface
EMR End of measuring range
ESD Electrostatically-sensitive group of components
ESD Electrostatic sensitive device
FC Flip chip
GND Ground
IC Integrated circuit
MC Machine controller
MMR Middle of measuring range
MTC Matrix tray changer
OSC Odd shaped components
P&P Pick&Place
PA Placement area
PCB Printed circuit board
SC Single conveyor
SC Station computer
SM Dual conveyor in Single conveyor mode
SMD Surface mounted device
SMR Start of measuring range
TH TwinHead
VS Vision system
WLAN Wireless Local Network
WT Waffle-pack tray
WTC Waffle-pack tray carrier
User manual SIPLACE X-Series 2 Operational safety
Software Version SR.601.xx 11/2005 US Edition 2.1 Safety instructions
27
2 Operational safety
2.1 Safety instructions
2.1.1 Conventions for the use of hazard symbols
This User Manual contains notes that must be observed to guarantee your personal safety and to
avoid damage to equipment. These notes are highlighted by warning triangles and are indicated
as follows according to the level of risk:
DANGER or
as used in this User Manual means that death, severe injury or considerable damage to equip-
ment
will
occur if the danger instructions are not followed.
WARNING or
as used in this User Manual means that death, severe injury or considerable damage to equip-
ment
may
occur if the warning instructions are not followed.
CAUTION or
as used in this User Manual means that slight injury or damage to equipment may occur if the cau-
tion instructions are not followed.
PLEASE NOTE
as used in this User Manual provides information on the product or indicates a part of the User
Manual that requires particular attention.
2.1.2 Qualified personnel
Qualified or adequately trained personnel means that these people are familiar with the setting up,
operation and preventive maintenance of automatic placement systems and add-on devices and
are suitably qualified, e.g.
have been trained, instructed or authorized to switch on and off, isolate, earth and identify
electrical circuits and system components in accordance with normal safety standards.
have been trained or instructed in the upkeep and use of appropriate safety equipment in ac-
cordance with normal safety standards.
have received first aid training.