X3_X4_Series machine - 第37页
User manual SIPLAC E X-Series 2 Operational safety Software Vers ion SR.601.xx 11/ 2005 US Ed ition 2.2 Warning labels 37 2.2.2 W arning label W202 on the gantries Fig. 2.2 - 3 Warning label W202 o n the gantries Pos. W2…

User manual SIPLACE X-Series 2 Operational safety
Software Version SR.601.xx 11/2005 US Edition 2.2 Warning labels
37
2.2.2 Warning label W202 on the gantries
Fig. 2.2 - 3 Warning label W202 on the gantries
Pos. W202, item no. 03009341-01

2 Operational safety User manual SIPLACE X-Series
2.2 Warning labels Software Version SR.601.xx 11/2005 US Edition
38
2
Pos. W202 in Fig. 2.2 - 3, item no. 03009341-01
(number per X2 placement machine: 6, X3 placement machine: 7, X4 placement machine: 8)
WARNING 2
Powerful permanent magnetic fields inside the machine
DANGER 2
Risk of death for persons with active implants (e.g. pacemakers, insulin pumps, defibrillators).
2
WARNING
Danger of crushing for persons with passive metal implants (e.g. plates, screws).
Do not reach into the machine or bend towards it when the protective covers are open.
Do not bring any metal objects into the area.