X3_X4_Series machine - 第411页

User manual SIPLAC E X-Series 7 Station extensions Software Version SR.601.xx 11/2005 US Edition 7.3 Component camera for the TwinHead, FC camera 411 7.3 Component camera for t he T winHead, FC camera 7.3.1 S tationary P…

100%1 / 464
7 Station extensions User manual SIPLACE X-Series
7.2 Sensor for the component reject bin Software Version SR.601.xx 11/2005 US Edition
410
7.2 Sensor for the component reject bin
Item no. 00116848-xx
The sensor for the component reject bin monitors whether the reject bin is seated correctly in its
mount.
If the reject bin was not inserted correctly, the placement machine cannot be started.
If the reject bin jumps out of its mount during the placement process, the machine is stopped
immediately to avoid a head crash.
Each reject bin can be monitored by a separate sensor.
PLEASE NOTE 7
If a 20-segment Collect&Place head is used, then the sensor for the component reject bin is
absolutely essential.
User manual SIPLACE X-Series 7 Station extensions
Software Version SR.601.xx 11/2005 US Edition 7.3 Component camera for the TwinHead, FC camera
411
7.3 Component camera for the TwinHead, FC camera
7.3.1 Stationary P&P component camera (type 25) 16 x 16, digital (FC camera)
Item no. 00119718-xx
7
Fig. 7.3 - 1 Stationary P&P component camera (type 25) 16 x 16, digital (FC camera)
(1) Camera housing with integral camera and camera amplifier
(2) Glass plate - over the illumination and lens levels
7
7 Station extensions User manual SIPLACE X-Series
7.3 Component camera for the TwinHead, FC camera Software Version SR.601.xx 11/2005 US Edition
412
7.3.1.1 Position of the component vision cameras for the TwinHead on the
X3 placement machine
7
Fig. 7.3 - 2 Position of the component vision cameras for the TwinHead on the X3 placement machine
(1) Assembly position for the CO vision camera (stationary, P&P (type 33) 55 x 45), location 3
(2) Assembly position for the CO vision camera (stationary, P&P (type 25) 16 x 16), location 3