D-serie level 1 EN - 第130页
P&P and TWIN Heads Room for Your Sketches and Notes Functions S tuden t Guide Advanced Level 1 SIPLACE D-Series P&P and TWIN Heads EN 05/2007 7-16

P&P and TWIN Heads
Functions Room for Your Sketches and Notes
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 P&P and TWIN Heads
7-15
7.5 Room for Your Sketches and Notes

P&P and TWIN Heads
Room for Your Sketches and Notes Functions
Student Guide Advanced Level 1 SIPLACE D-Series
P&P and TWIN Heads EN 05/2007
7-16

Component Handling
Technical Data - Changeover Tables Overview
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 Component Handling
8-1
8 Component Handling
8.1 Overview
8.1.1 Technical Data - Changeover Tables
Feeder capacity for D1/
D2 machines:
90 tracks for 8 mm tapes with 3x8 mm feeders
60 tracks for 8 mm tapes with 2x8 mm feeders
Feeder capacity for D4
machines:
144 tracks for 8 mm tapes with 3x8 mm S feeders
96 tracks for 8 mm tapes with 2x8 mm S feeders
Locations for D1/D2
machines:
2 changeover tables with integrated waste tape container
15 feeder positions, each one with 30 mm on each changeover table
Option: Waffle Pack Changer (10 feeder positions – 30 mm wide)
Locations for D4
machines:
4 changeover tables with integrated waste tape container
12 feeder positions, each one with 30 mm on each changeover table
Feeders: Tapes, bulkcase, linear feeder, Siplace S feeder (F4, F5,S20, S23, S25HM,
S27HM, HS50, HS50+,HS60), OEM feeder, surftape feeder (8, 12, 16, 24
mm), manual trays
Interface to the
machine
Plug-in connection to machine
- Power supply
- CAN bus connection
- Closing the safety loop
- Compressed air connection
- Splice point recognition connection (optional)
Changeover table
height
depend from the machine height:
830 mm ± 15 mm (standard)
900 mm ± 15 mm (SMEMA)
930 mm ± 15 mm (SMEMA)
950 mm ± 15 mm (SMEMA)