D-serie level 1 EN - 第163页

SITEST New Functions in SITEST Calibr ation Basics S tude nt Guide Advanced Level 1 SIPLACE D-Series EN 05/2007 SITEST 9-19 Head Dat a 9-12: Head modularity - head data Legend 1. Select and set the relevant head typ e fo…

100%1 / 200
SITEST
Calibration Basics New Functions in SITEST
Student Guide Advanced Level 1 SIPLACE D-Series
SITEST EN 05/2007
9-18
9-11: Firmware download
In the Can FW folder there are all current Firmware versions of all axes, tables etc.
Legend
1. The system checks this folder, to see whether there is a newer version of the firmware for the
respective axis, table etc.. If there exist a new firmware version, this new version will be offered and
could be downloaded for example to the star- axis.
2. You can also copy a new firmware version manually into the CAN FW folder. Click on the
Copy firm-
ware file to pool
. An Explorer menu will open, in which you can directly copy the new firmware
version from a USB stick etc. into the CAN FW folder. The firmware version you have selected is
now present in the selection menu (see (1)).
9.3.7.3 Head Modularity for SIPLACE D-Series
X , select
Settings
from the SITEST menu and then
Head exchange
.
SITEST
New Functions in SITEST Calibration Basics
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 SITEST
9-19
Head Data
9-12: Head modularity - head data
Legend
1. Select and set the relevant head type for the head replacement.
2. Select and set the relevant camera type for the selected head type or head replacement.
3. Shows the data for the head installed. The current BIOS and application version, the head type and
the camera type of the installed head.
Axis Data
9-13: Head modularity - axis data
SITEST
Calibration Basics New Functions in SITEST
Student Guide Advanced Level 1 SIPLACE D-Series
SITEST EN 05/2007
9-20
Legend
1. This is where the axis data (Z and star axes) can be written from the head EPROM to the machine
data. You can also write the Z and star axis data from the machine data to the head EPROM.
Function
9-14: Head modularity - function
Legend
1. After the head has been replaced, this function enables you to calibrate this head directly in the head
modularity menu. Of course it is also possible to calibrate the other heads with this function. The new
head and other heads can also be calibrated with SITEST, at
Calibrate machine...
,
All heads and
cameras...
.
2. The same applies as in(1). After the head exchange you can directly do a head- mapping. The head
mapping function can be found at
Calibrate machine
,
Head Mapping
.