SIPLACE Vision
Optical Fiducial Models Error Processing at Fiducial Recognition During Placement Operations
Student Guide Advanced Level 1 SIPLACE D-Series
SIPLACE Vision EN 05/2007
10-16
10.1.4.2 Teaching Fiducials
If, during production, lot fluctuation changes a fiducial to such a degree that reteaching is required, a
fiducial error signal will be issued and placement will stop until the fiducial shape has been re-
recorded.The system again switches over to the fiducial teaching menu, in this case, but into the fiducial
geometry menu, not the position teaching menu. This retaught shape is saved and sent to the SIPLACE
Pro computer, where it is stored and sent on to all stations in the X line.
10-4: Teaching SC fiducial 01 0505
Fiducial teaching submenus (from left)
1. Return to main menu Place
2. Fiducial selection list
The list only shows the fiducials for the PCB
currently defined.
3. Results of centering and measurement steps
4. Fiducial geometry teaching menu
5. Setting the illumination type and strength
6. Defining algorithms
7. Fiducial position teaching menu
SIPLACE Vision
Error Processing at Fiducial Recognition During Placement Operations Room for Your Sketches and Notes
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 SIPLACE Vision
10-17
10.2 Room for Your Sketches and Notes
SIPLACE Vision
Room for Your Sketches and Notes Error Processing at Fiducial Recognition During Placement Operations
Student Guide Advanced Level 1 SIPLACE D-Series
SIPLACE Vision EN 05/2007
10-18