D-serie level 1 EN - 第194页
SIPLACE Measuring Tools Adjustment Aid Set for C&P DLM [00327005-01] Scope of Delivery S tuden t Guide Advanced Level 1 SIPLACE D-Series SIPLACE Measuring T o ols EN 05/2007 11 - 1 0 1 1.12 Adjustment Aid Set for C&a…

SIPLACE Measuring Tools
Scope of Delivery Calibration Tools for Vision Systems
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 SIPLACE Measuring Tools
11-9
11.10 Calibration Tools for Vision Systems
11.11 Z-End Stopper Star Gauge for C&P6/12 [03019865-01]
Application:
The calibration tool [003010565-xx] is used to
calibrate the C&P6/12 placement heads in the
D/X and HF machines.
A second calibration tool is available for the
C&P20 head of the X-series:
Calibration tool [03034148-01] version for
C&P20 head (for component camera system
type 23)
Another calibration tool is available for
machines with 4xx software:
Calibration tool [00316308-03] version II
transparent
The various calibration tools for the different
machine types are listed here for the sake of
completeness.
Z-end stopper star gauge for C&P6 and
C&P12
Application:
The gauge is used to set the end stopper of the
C&P head Z-axis.

SIPLACE Measuring Tools
Adjustment Aid Set for C&P DLM [00327005-01] Scope of Delivery
Student Guide Advanced Level 1 SIPLACE D-Series
SIPLACE Measuring Tools EN 05/2007
11-10
11.12 Adjustment Aid Set for C&P DLM [00327005-01]
Complete set: Item No. 00327005-01
1. Gauge forstar [00326164-01]
2. Test probe 1.4 mm [00326160-01]
3. Test probe 1.5 mm [00326161-01]
4. Test probe 1.6 mm [00326162-01]
5. Test probe 1.0 mm [00376656-01]
6. Distance gauge [00325445-01]
Measuring tools Type of application
Star gauge Setting the star zero point correction
Test probe 1.4 mm Setting the distance between the DP station read head and the glass sheet of the
sleeve
Test probe 1.5 mm
Test probe 1.6 mm
Test probe 1.0 mm Setting the distance of the Z-axis down light barrier to the sleeve shaft
Distance gauge Setting the distance of the valve plunger to the star

SIPLACE Measuring Tools
Scope of Delivery Adjustment Aid for Changeover Table [00120040-01]
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 SIPLACE Measuring Tools
11-11
11.13 Adjustment Aid for Changeover Table [00120040-01]
This setting gauge is not provided in the SIPLACE Pro computer delivery package and needs to be
ordered separately for a new line.
Application:
The adjustment aid is needed for calibration of
the changeover table.
It is only needed (or can only be used) for
SIPLACE S tables.
ATTENTION:
Never use more than one adjustment
aid for pickup position calibration on
one changeover table.
Exception: You may occasionally need
to use another adjustment aid for a
different side of the machine or line.