D-serie level 1 EN - 第48页
Overview Assemblies Gantry S tuden t Guide Advanced Level 1 SIPLACE D-Series Overview EN 05/2007 3-24 Additional X motor cooling is pe rformed at the resp ective pickup posit ion. The diag ram above s hows the following …

Overview
Gantry Assemblies
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 Overview
3-23
X-Axis Technical Data
3.4.7.3 Y-Axis Construction
3-18: Y-Axis Design and Fan Positions (D4)
Legend
Drive A.C. servo motor/toothed belt
Maximum speed 2.5 m/sec.
Travel range 375 mm
Distance measuring system Incremental scale
Measuring length 400 mm
Scale length 420 m
Resolution 1 µm
1 Gantry 1 5 Guide system
2 Gantry 2 6 Linear motor secondary part
3 Gantry 3 7 Measuring system
4 Gantry 4 8 Linear motor primary part

Overview
Assemblies Gantry
Student Guide Advanced Level 1 SIPLACE D-Series
Overview EN 05/2007
3-24
Additional X motor cooling is performed at the respective pickup position. The diagram above shows the
following pickup positions:
Pickup position for gantry 1 (A)
Pickup position for gantry 4 (B)
Pickup position for gantry 2 (C)
Pickup position for gantry 3 (D)
Do not cover the fan and service the filter fitted there.
Y-Axis Technical Data
Drive Direct, linear motor
Maximum speed 2.5 m/sec.
Travel path of gantries, calculated from the center
of the machine
Gantry 1 - 688.5 mm
Gantry 2 - 768.5 mm
Gantry 3 - 688.5 mm
Gantry 4 - 768.5 mm
Distance measuring system Incremental scale
Scale length D1/D2/D3: 1960 mm, D4: 1530 mm
Resolution 1 µm

Overview
C&P12 Head DLM3 Assemblies
Student Guide Advanced Level 1 SIPLACE D-Series
EN 05/2007 Overview
3-25
3.4.8 C&P12 Head DLM3
3.4.8.1 General
3-19: C&P12 Head DLM3
Legend
Option: Digital camera SST.29 for the C&P12 head and component sensor [00118021-xx] for 0201
placement.
1 Vacuum generator 4 Air blast valve
2 Turning station (DP axis) 5 Silencer
3 Star with 12 sleeves (star axis) 6 Component Camera