OM-1650-001_w - 第15页

OM-1650 12 6. Pattern Program (5) Lighting Level (Coax) Select the brightness level (one of the options described below) of the coaxial lighting for the PEC recognition camera in this text box. [Std], [-80%], [-60%], [-4…

100%1 / 39
OM-1650
11
6. Pattern Program
[10] Overall PCB BBR
(1) Mode
Select one of the following options for the overall PCB BBR function.
Disable
: The overall PCB BBR detection function is not used.
Enable
: The overall PCB BBR detection function is used.
(2) X [mm], Y [mm]
When "Enable" is selected in the "Mode" text box, the coordinates (X
and Y) of the bad mark should be set for the overall PCB BBR detection
function.
Note
Overall PCB BBR Detection Function
When there are a few unit PCB's with a bad mark and most of the unit
PCB's are of good quality, then use the overall PCB BBR function.
Before a bad mark detection for each unit PCB, perform overall PCB BBR
detection. If any bad mark is not detected in overall PCB BBR detection,
then all the unit PCB's are regarded as good PCB's and the unit PCB BBR
detection is not performed.
Placement Coordinate Reference (No)
X (Horizontal)
Y (Vertical)
Bad Mark for Overall PCB BBR Function
Bad Marks
F6
Notice
When this function is set to "Enable", all the PCBs without a master
bad mark, are processed as good PCBs.
When a bad mark has been placed on any unit PCB, take care not
to forget placing a master bad mark.
(3) Value of threshold
Set the threshold value for bad mark determination.
Data Input Range:
1 to 255
Reference
Refer to "9. Bad Mark Camera Test" for the threshold value.
(4) Inspection Area [mm]
Set the area for the PEC recognition camera to detect a bad mark.
Data Input Range:
0.1 to 1.0
1006-001
OM-1650
12
6. Pattern Program
(5) Lighting Level (Coax)
Select the brightness level (one of the options described below) of the
coaxial lighting for the PEC recognition camera in this text box.
[Std], [-80%], [-60%], [-40%], [-20%],
[+20%], [+40%], [+60%], [+80%], [Off]
(6) Lighting Level (Ring)
Select the brightness level (one of the options described below) of the
ring lighting for the PEC recognition camera in this text box.
[Std], [-80%], [-60%], [-40%], [-20%],
[+20%], [+40%], [+60%], [+80%], [Off]
(7) Lighting Level (Option)
Select the brightness level of the optional lighting level for the PEC
recognition camera in this text box.
[Std], [-80%], [-60%], [-40%], [-20%],
[+20%], [+40%], [+60%], [+80%], [Off]
(8) Image
Set the image of the bad mark for the overall PCB BBR detection.
Black (E/NR)
: A black mark (E/NR) is used.
White (E/R)
: A white mark (E/R) is used.
1006-001
OM-1650
13
6. Pattern Program
6.2 Placement Data (P Data)
When "Mode" in "Unit PCB BBR" is set to "Normal", set the bad mark
coordinates in the "P-No. 1" step data box in the Placement Data (P Data).
[1] [2]
"Placement Data (P Data)" Tab Sheet F7
[1] X[mm] and Y[mm] in "P-No. 1" Step
Set the coordinates (BX1, BY1) of the bad mark based on the pattern origin.
[2] C for "P-No. 1" Step
Set the control command to "B".
Placement Coordinate
Reference Point
(OX1,OY1)
(OX
2,OY2)
Pattern Origin (OX
3,OY3)
Pattern 1
Bad Mark Affixing Position (BX
1,BY1)
Pattern 2
Pattern 3
F8
1006-001