Replacing Consumable Parts >> Vacuum Pump Filter Element MEC-CP842-1.0E 6-7 6.5 V acuum Pump Filter Element Point Air drawn into the pump should be cle an. The filter element should therefore be replaced when it be…

100%1 / 232
Replacing Consumable Parts >> Conveyor Belts
6-6 MEC-CP842-1.0E
The standard conveyor belt tension values are as stated in the diagram below.
Check the tension using a tension meter at the points indicated by the arrows as
shown.
7 Replace the panel lifter. The top edge of the lifter must align with the center of
the conveyor belt. Also, if necessary, loosen the horizontal adjustment bolts to
align with the carrier.
298Hz ± 15
71.888 mm
C746M4006
Replacing Consumable Parts >> Vacuum Pump Filter Element
MEC-CP842-1.0E 6-7
6.5 Vacuum Pump Filter Element
Point
Air drawn into the pump should be clean. The filter element should therefore be
replaced when it becomes excessively dirty.
Procedure
Loosen the filter case holder, then extract the filter case by pulling it downward. After
extracting the filter case, replace the filter element.
WARNING
• Turn the main power off before performing this procedure.
• Do not touch the vacuum pump immediately after operation
because it may be extremely hot. Allow the pump to cool before
beginning this procedure.
C746M4007
Vacuum pump
Air filter
Flter case holder
Filter case
Filter element
Replacing Consumable Parts >> Vacuum Pump Belt
6-8 MEC-CP842-1.0E
6.6 Vacuum Pump Belt
Point
The vacuum pump belt should be replaced when broken or damaged.
Procedure
1 Remove the bracket bolts that secure the vacuum pump table, then disconnect
the cable connectors.
2 Pull out the vacuum pump together with the table.
WARNING
• Turn the main power off before performing this procedure.
• Do not touch the vacuum pump immediately after operation
because it may be extremely hot. Allow the pump to cool before
beginning this procedure.
C746M4008
Bolts
Connectors
Table
Connectors
C746M4009
Vacuum pump