MEC-CP842-1.0E.pdf - 第125页

Replacing Consumable Parts >> Vacuum Pump Motor MEC-CP842-1.0E 6-17 6.8 V acuum Pump Motor Procedure 1 Pull out the vacuum pump. (For this procedure, refer to section 6.6 " V acuum Pump Belt"). 2 Use cali…

100%1 / 232
Replacing Consumable Parts >> Vacuum Pump Internal Vanes and Bearings
6-16 MEC-CP842-1.0E
7 Place the liners and bearing retainers on side plates "A" and "B".
Note: Even if the number of liners and their combinations are assembled in the same manner as
when disassembled, there may be some play when the shaft rotates.
The number of liners and the liner thickness should therefore be adjusted as necessary to
eliminate this play.
8 Verify that there is no contact between the rotor and the side plates when the
rotor is rotated while pushing and pulling the rotor shaft.
9 Complete the vacuum pump reassembly by reversing steps 1 to 6 of the disas-
sembly procedure, then reconnect the cable connectors.
C746M4019
Bearing retainer
Bearing retaine
r
Liner
Liner
C746M4T02
Liner Thickness
Color Coded
0.03 mm
Red
0.05 mm
Yellow
0.10 mm
Black
0.20 mm
No color
C746M403
0
Side plate A
Side plate B
Shaft
Shaft
C746M4031
Conectors
Conectors
Replacing Consumable Parts >> Vacuum Pump Motor
MEC-CP842-1.0E 6-17
6.8 Vacuum Pump Motor
Procedure
1 Pull out the vacuum pump. (For this procedure, refer to section 6.6 " Vacuum
Pump Belt").
2 Use calipers to measure the distance between the vacuum pump pulley and the
motor pulley, and make a note of this measured value.
WARNING
• Turn the main power off before performing this procedure.
• Do not touch the vacuum pump immediately after operation
because it may be extremely hot. Allow the pump to cool before
beginning this procedure.
C746M4013
Vacuum pump
C746M4032
L
Motor pulley
Vacuum pump pulley
Replacing Consumable Parts >> Vacuum Pump Motor
6-18 MEC-CP842-1.0E
3 Remove parts that hinder motor replacement. These parts include the vacuum
pump, duct, and the belt.
4 Remove the motor, then remove the pulley from the motor.
5 Mount the pulley on the new motor, then set the motor and vacuum pump on
the base. The bolts that secure the pulley, motor, and vacuum pump should be
tightened finger-tight at this time.
Final tightening should be completed after adjusting the pulley deviation and
the distance between the vacuum pump pulley and motor pulley (distance noted
at step 2). The pulley deviation should be 0.3 mm or less.
C746M4033
Duct
Vacuum pump
Belt
C746M4034
Pulley
Motor
C746M4035
Reference-side pulley
0.3 mm or less
0.3 mm or less
0.3 mm or less