Troubleshooting >> Servo Syst em Troubleshooting 8-18 MEC-CP842-1.0E AC Servopack Check List for Troubleshooting Alarm Alarm Name Status Cause Check Item Remedy A.51 Overspeed • Occurs at control power ON. • Occurs…

100%1 / 232
Troubleshooting >> Servo System Troubleshooting
MEC-CP842-1.0E 8-17
AC Servopack Check List for Troubleshooting
Alarm Alarm Name Status Cause Check Item
Remedy
A.30 Regenerative
Error Detected
· Occurs at control power ON.
· Occurs at main power ON.
· Servopack defective.
· Wiring to regenerative resistor
defective.
· Servopack defective.
· Incorrect regenerative resistor
wiring.
· Regenerative resistor
disconnected.
· Check the wiring to regenerative
resistor.
· Servopack defective.
· Check that wiring to the
regenerative resistor is proper.
· Check the regenerative
resistance value.
· Replace the Servopack.
· Check the regenerative value
and correct the wiring.
· Replace the Servopack.
· Manually correct the wiring of the
external regenerative resistor.
· Replace the external
regenerative resistor.
A.32 Regenerative
overload
· Occurs at control power ON.
· Occurs at normal operation.
· Servopack defective.
· Parameter Pn600 set value is
not correct when a regenerative
resistor is mounted externally.
· Servopack defective.
· Check that parameter Pn600 set
value is correct.
· Servopack defective.
· Replace the Servopack.
· Set parameter Pn600 correctly.
· Replace the Servopack.
C746M5T14
A.40 Overvoltage · Occurs at control power ON.
· Occurs at main power ON
or when motor is in operation.
· Servopack defective.
· Excessive power supply voltage.
· Servopack defective.
· Check the AC power supply
voltage. (Is there excessive
voltage variation?)
· Servopack defective.
· Replace the Servopack.
· Set the AC power supply voltage
to a value in the normal setting
range.
· Replace the Servopack.
A.41 Undervoltage · Occurs at control power ON.
· Occurs at main power ON
or when motor is in operation.
· Servopack defective.
· Power supply voltage is
excessively small.
· Servopack defective.
· Power supply variation is large
and power supply is reduced.
· Check the AC power supply
voltage. (Pay attention to
different power supply applied.)
· Servopack defective.
· Check that a momentary power
failure has not occurred.
· Replace the Servopack.
· Set the AC power supply voltage
to a value in the normal setting
range.
· Replace the Servopack.
Troubleshooting >> Servo System Troubleshooting
8-18 MEC-CP842-1.0E
AC Servopack Check List for Troubleshooting
Alarm Alarm Name Status Cause Check Item
Remedy
A.51 Overspeed • Occurs at control power ON.
• Occurs at main power ON
or when motor is in
operation.
• Servopack defective.
• Incorrect motor wiring.
• Incorrect encoder wiring.
• Servopack defective.
• Check that the motor rotating
direction is correct (phases U, V
and W wiring).
• Servopack defective.
• Replace the Servopack.
• Manually correct the motor
wiring.
• Manually correct the encoder
wiring.
• Replace the Servopack.
A.71
A.72
Overload for
Instantaneous
Maximum Load
Overload for
Continuous
Minimum Load
• Occurs at control power ON.
• Occurs at main power ON
or when motor is in
operation.
• Servopack defective.
• Incorrect motor wiring.
(imperfect wiring or connection)
• Incorrect encoder wiring.
(imperfect wiring or connection)
• Servopack defective.
• Check that the connnection is
correct and that the motor wiring
does not have an open phase.
• Servopack defective.
• Excessive load on servo.
• Replace the Servopack.
• Manually correct the motor
wiring.
• Manually correct the encoder
wiring.
• Replace the Servopack.
• Check for excessive load on
components driven by the servo.
C746M5T15
A.73 Dynamic Brake
Overload
• Servopack defective. • Replace the Servopack.
A.74 Overload of
in-rush Current
Limit Resistor
• Occurs at control power ON.
• Occurs at main circuit
power supply ON/OFF.
• Servopack defective.
• The allowable frequency of
in-rush current limit resistor at
power ON/OFF is exceeded.
• Servopack defective.
• Check that the allowable
frequency of in-rush current limit
resistor (5 times/min) is not
exceeded.
• Check that the Servopack fan is
operating.
• Check that the fan for the control
board is operating.
• Check the ambient temperature
of the Servopack exceeds 35 °C.
• Excessive load on servo.
• Replace the Servopack.
• Reduce the main circuit power
supply ON/OFF frequency to
5 times/min.
• Replace the Servopack.
A.7A Heat Sink
Overheated
• Occurs at main power ON
or when motor is in
operation.
• Servopack defective.
• Ambient temperature of the
Servopack exceeds 35 °C.
• Replace the Servopack.
• Set the ambient temperature of
the Servopack to 35 °C or less.
• Check for excessive load on
components driven by the servo.
Troubleshooting >> Servo System Troubleshooting
MEC-CP842-1.0E 8-19
AC Servopack Check List for Troubleshooting
Alarm Alarm Name Status Cause Check Item
Remedy
A.81 Absolute Encoder
Backup Error
· Occurs at power ON.
(Pn002.2 = 0)
When used as absolute
encoder.
· Occurs at power ON.
(Pn002.2=1)
· Turn ON the power supply to the
absolute encoder for the first
time.
· Both PG power supply (+5V)
from the Servopack and the
battery power supply are failed.
· Absolute encoder defective.
· Servopack defective.
· Servopack defective when used
as incremental encoder.
· Check that the absolute encoder
has been set up.
· Check that the power is supplied
to the encoder side.
· Encoder defective at alarm
occurrence even by setting up
the absolute encoder again.
· Servopack defective if nothing is
wrong in the above check.
· Check that the battery is
connected correctly.
· Check that the battery voltage is
not reduced to 2.7 V or less.
· Servopack defective if nothing is
wrong in the above check.
· Set up the encoder.
· Set up the encoder after
restoring the power supply to
the encoder (by replacing the
battery, etc.).
· Replace the encoder.
· Replace the Servopack.
· Replace the Servopack.
C746M5T16
A.82 Encoder
Checksum Error
· Occurs at power ON or
when motor is in
operation.
· Encoder defective.
· Servopack defective.
· Set up the encoder. Replace
the motor if the alarm occurs
frequently.
· Replace the Servopack.
A.83 Absolute Encoder
Battery Error
· Occurs at power ON.
(Pn002.2=0)
When used as absolute
encoder.
· Imperfect connection or
disconnection of battery.
· Battery voltage is reduced to the
specified value (2.7 V) or less.
· Servopack defective.
· Connect the battery properly.
· Replace the battery and turn
ON the encoder power supply again.
· Replace the Servopack.
· Replace the Servopack.
A.84 Encoder Data
Error
· Occurs at power ON or
when motor is in
operation.
· Sensor in the encoder reads the
data improperly.
· Encoder malfunctions.
· Servopack defective.
· Turn ON the encoder power
supply again.
Replace the motor if the alarm
occurs frequently.
· Correct the wiring processing
around the encoder.
· Replace the motor if the alarm
occurs frequently.
· Replace the Servopack.
· Servopack defective when used
as incremental encoder.
· Occurs at power ON.
(Pn002.2=1)