Trans lation Fo rmats ProM aster 25 00 User Manua l D-3 Instrument Control C odes The instrum ent co ntrol cod e is a 1-d igit num ber tha t signals o r cont rols data transfers. Specifically, the in strument control cod…

100%1 / 448
Translation Formats
D-2 ProMaster 2500 User Manual
Below you will find a list, in ascending numerical order, of all the
translation formats supported by the programmer. Following the list is a
description and, in most cases, an example of each translation format,
presented in order by format number.
* This alternate code is used to transfer data without the STX start code and the ETX end
code.
** This alternate code is used to transfer data using the SOH start code instead of the
usual STX.
Format Code Format Code
ASCII-BNPF 01 (05*) Fairchild Fairbug 80
ASCII-BHLF 02 (06*) MOS Technology 81
ASCII-B10F 03 (07*) Motorola EXORcisor 82
Texas Instruments Intel Intellec 8/MDS 83
SDSMAC (320) 04 Signetic Absolute Object 85
5-level BNPF 08 (09*) Tektronix Hexadecimal 86
Formatted Binary 10 Motorola EXORmacs 87
DEC Binary 11 Intel MCS-86 Hex Object 88
Spectrum 12 (13*) Hewlett-Packard 64000
Absolute 89
POF 14
Absolute Binary 16 Texas Instruments
LOF 17 SDSMAC 90
ASCII-Octal Space 30 (35**) JEDEC format (full) 91
ASCII-Octal Percent 31 (36**) JEDEC format (Kernel) 92
ASCII-Octal Apostrophe 32 Tektronix Hexadecimal
ASCII-Octal SMS 37 Extended) 94
ASCII-Hex Space 50 (55**) Motorola 32 bit (S3 record) 95
ASCII-Hex Percent 51 (56**) Hewlett-Packard UNIX
ASCII-Hex Apostrophe 52 Format 96
ASCII-Hex SMS 57 Intel OMF 386 97
ASCII-Hex Comma 53 (58**) Intel OMF 286 98
RCA Cosmac 70 Intel Hex-32 99
Translation Formats
ProMaster 2500 User Manual D-3
Instrument Control Codes
The instrument control code is a 1-digit number that signals or controls
data transfers. Specifically, the instrument control code can be used to
implement a form of remote control that provides peripherals with flow
control beyond that provided by software handshaking. When using
computer remote control, the instrument control code is sent immediately
preceding the 2-digit format code. The three values of the instrument
control code and associated functions are described below.
Note: X-ON character is a CTRL-Q, or 11 hex.
X-OFF character is a CTRL-S, or 13 hex.
PUNCH-ON character is a CTRL-R, or 12 hex.
PUNCH-OFF character is a CTRL-T, or 14 hex.
0-Handshake Off
Input Function: Send X-OFF to stop the incoming transmission. Send
X-ON to resume transmission.
Output Function: Data transmission will be halted upon receipt of an
X-OFF character; transmission will resume upon
receipt of an X-ON character.
1-Handshake On
Input Function: Transmit an X-ON character when ready to receive
data; transmit X-OFF if the receiver buffer is full;
transmit an X-ON if the receiver buffer is empty;
transmit an X-OFF after all the data are received.
Output Function: Transmit a PUNCH-ON character prior to data
transmission. Data transmission will be halted upon
receipt of an X-OFF character and will resume upon
receipt of an X-ON character. A PUNCH-OFF
character is sent when the transmission is completed.
2-X-ON/X-OFF
Input Function: Send X-OFF to stop the incoming transmission. Send
X-ON to resume transmission.
Output Function: Transmit data only after receiving an X-ON
character. Data transmission will be halted upon
receipt of an X-OFF character; transmission will
resume upon receipt of an X-ON character.
Translation Formats
D-4 ProMaster 2500 User Manual
General Notes
Some information about data translation is listed below:
Note: Formats 10, 11, and 89 do not function properly unless you select NO
parity and 8-bit data.
Compatibility
When translating data, you may use any remote source that produces
formats compatible with the descriptions listed in this section.
Formats with Limited Address
Fields
Some formats are not defined for use with address fields greater than
64K. Thus, if you transfer a block greater than 64K, the address fields that
would be greater than 64K may wrap around and overwrite data
transferred in previous data records. Formats 70 through 86, and 90 may
exhibit this characteristic.
Hardware Handshaking
Hardware handshaking may be used if compatible with the host
interface by connecting the appropriate lines at the serial port interface.
Hardware handshake (CTS/DTR) is enabled as the default. However, if
those signals aren’t connected, the programming electronics sense this
and communicate using software handshake (XON/XOFF). The
programmer always uses software handshake regardless of whether
hardware handshake is enabled.
Leader/Trailer
During output of all formats except 89 (HP 64000), a 50-character leader
precedes the formatted data and a 50-character trailer follows. This
leader/trailer consists of null characters. If the null count parameter is set
to FF hex, then the leader/trailer is skipped. To set the null count, go to
the More Commands/Configure/Edit/Communication Parameters
screen and set the Number of Nulls parameter. If in CRC, use the CRC
U
command to set the null count.