00196390-0102 - 第41页

Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3 10/2008 Edition 41 : Lift out the clamp and the hose band. 2 : Remove the pressure pl ate above and below the hose band. The upper one is glued to a …

100%1 / 54
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
40
: Loosen the four inner lacquered screws for the clamp by one turn.
2
2
: Loosen the four outer screws for the clamp on the gantry.
2
2
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
41
: Lift out the clamp and the hose band.
2
: Remove the pressure plate above and below the hose band.
The upper one is glued to a metal clip. Disconnect the pressure plate from the metal clip using
the knife.
2
Both pressure plates are no longer needed. They are replaced by the new ones from the retrofit
kit. 2
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
42
: Loosen the two screws from the underside of the upper clamp and disconnect the wiring har-
ness and compressed air hoses.
2
2
2
2
2
2
2
Loosen the two
screws