00196390-0102 - 第47页

Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3 10/2008 Edition 47 : Screw down the four inne r screws tightly cross-wise using a torque of 0.7 +/- 0.2 Nm and then coat them with lacquer . Mark the…

100%1 / 54
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
46
: Lay a new pressure plate under the hose band in the clamp on the gantry.
2
: Glue two of the clamping plates again onto both metal clips of the clamp with the aid of the
double-sided adhesive tape.
: Lay one of these clamping plates with a metal clip onto the sevenfold hose and screw down
the package firmly as shown in the picture (4 screws). The screws must be secured using Loc-
tite 241.
2
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
47
: Screw down the four inner screws tightly cross-wise using a torque of 0.7 +/- 0.2 Nm and then
coat them with lacquer.
Mark the clamp on the upper side with a green point.
In this way one can recognize later whether new pressure plates have been installed.
2
2
: Loosen the topmost adhesive tape.
2
Retrofit instructions Sevenfold tube SIPLACE HF-series / X-series / D3
10/2008 Edition
48
: Lay the ribbon cables together with the hoses and the new pressure plates in the upper clamp.
Tighten the clamping using the new pressure plates so that the components can be adjusted
easily.
Align the clamp based on the existing adhesive joint.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Tighten two screws