SM-131-006.pdf - 第118页

Device Name Chip Mounter Block Name Page No. Unit Name Revision Model Item GXH -1 Chapter 5 Head Section 5. Location of Each Sensor 5.1 Location of NL-Axis Sensors and Stoppers • NL-Axis Orig in Position (1) After the NL…

100%1 / 325
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 5 Head Section
4. Replacement of Nozzle Shaft
Nozzle Shaft Assembly
4.3.2 Assembly of Cam Follower Section
Assemble the cam follower section
(located at the upper area of the
nozzle shaft) to the nozzle shaft with
two bolts (M1.6L3). (Fig. E33)
Tightening Torque:
720 gf/cm
(Use Screw Lock 1401B.)
(a) Attach the nozzle
shaft and cam
follower vertically
without leaving any
clearance between
Face A of the cam
follower and Face B
of the nozzle shaft. (Fig. E34)
(b) In principle, the disassembled cam follower section and nozzle shaft must be
reassembled.
Fig. E34 Attachment of Cam Follower Section
A
B
0406-001
5-16
M1.6L3
Fig. E33 Assembly of Cam Follower Section
to Nozzle Shaft
Cam Follower
Section
Nozzle Shaft
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 5 Head Section
5. Location of Each Sensor
5.1 Location of NL-Axis Sensors and Stoppers
NL-Axis Origin Position
(1) After the NL axis has been zeroed, check to see how the cam is shifted (transition)
before the NS axis is zeroed.
(2) After adjusting the NL-axis origin position as shown in Fig. E36, zero the NS axis.
Move the NS axis by -25°, -20°, 0°, 20°, and 25° and measure the amount of
transition (cam shift).
Specified Value: Loosen the coupling
of the NL axis and adjust the origin
position until the amount of transition
becomes "±0.01 mm or less".
B3105
B3102
B3104
(-) Limit Sensor
((-) Soft Limit)
(-) Mechanical Stopper
(+) Mechanical Stopper
(+) Limit Sensor
NL-Axis Basic Stroke
U/D Interlock
Photosensor
(mm)
19.0
0.3 to 0.4
0.5 ± 0.2
0.5
0.5
Fig. E35 Nozzle Level Axis
0.2
0.2
0.5
±
0.2
((+) Soft Limit)
NL-Axis Origin
Visual Check: Approx. 0.2 mm or less
Fig. E36 Cam Shift (Transition)
Fig. E37 Cam Shift (Transition)
0406-001
5-17
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model ItemGXH-1
Chapter 5 Head Section
5. Location of Each Sensor
5.2 Location of HL-Axis Sensors and Stoppers
HL-Axis Origin Position (Referential Value)
(1) Confirm that the NL-axis origin adjustment is already finished.
(2) Loosen the HL-axis coupling and adjust the stoke so that it can be "32±0.05 mm" as
shown below after the HL axis is zeroed.
Fig. E38 Head Level Axis
Photosensor
B3103
B3106
(-) Limit Sensor
(-) Mechanical Stopper
(+) Mechanical Stopper
(+) Limit Sensor
HL-Axis Origin
(mm)
24.0
1 ± 0.1
1
(0.5)
((-) Soft Limit)
((+) Soft Limit)
(0.5)
1 ± 0.2
1
HL-Axis Basic Stroke
Master Nozzle
(NL- and HL-Axis Origin Position)
Fig. E39 HL-Axis Origin Position
Design Value of Stroke: 32 mm
PCB Upper Surface Reference Point
0406-001
5-18