Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 5 Head Section
7. MSB Whole Cleaning and Lubrication Procedures
(27) Apply DAPHNE EPONEX No. 1 grease to the top block section cam follower and travel
surface thinly. <See Fig. E76>
Fig. E76
(28) Detach the head section attaching jig (a lid for preventing jumping out nozzle shaft).
Fig. E77
Com Follower
Travel Surface
Cam Follower
To
p
Block
Side View
No. 1 Nozzle Position
View of Head Bottom Surface
No.1 ノズル
No.1
M1.6×L4
Head section
Attaching Jig
0605-001
5-42
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 5 Head Section
7. MSB Whole Cleaning and Lubrication Procedures
(29) Attach the linear measure sensor emission side.
- Attaching direction of the linear measure sensor: Turn the “white mark” <shown in Fig.
E78> to the light receiving side when the poison is the origin.
- Fixating position of the linear measure sensor: Fix it at the center of the slit shown in
Fig. E79.
- Replace the 2-M1.6×L4 bolts with new one and dispose of the old bolts.
- Apply the screw lock (Three Bond 1401B) to the M1.6×L4 slightly and tighten it with
a tightening torque (Torque Driver <See Fig. E79>) by 7.5 cNm (0.76 kg f cm).
Fig. E78
Fig. E79
M1.6×L4
M1.6×L4
Three Bond 1401B
Center Position
of the slit
View of Head Bottom Surface
Connector
White Mark
Positioning Pin
(Origin Position)
Linear Measure
Sensor Light
Receiving Side
No. 1 Nozzle Position
Direction: At 3:00
o’clock by clock
position
Direction: Just at
12:00 o’clock by
clock
p
osition
View of Head Bottom Surface
0605-001
5-43
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 5 Head Section
7. MSB Whole Cleaning and Lubrication Procedures
(30) Attach the Large and small diffusion plates of the head bottom surface shown in
Fig. E80.
(Large Diffusion Plate: 3-M1.6×L4 bolts, Small Diffusion Plate: 2-M1.6×L4 bolts)
- During this attaching operation, pay attention to the transparent area of the linear
measure sensor tip side section because the linear measure sensor protection cap is put
off at this time so, there is a possibility that the wrench or fingers touches that section.
Please take action to protect this section such as applying a wrench or covering this
section with plastic wrap.
- Replace the 5-M1.6×L4 bolts with new one and dispose of the old bolts.
- Apply the screw lock slightly (Three Bond 1401B) to the M1.6×L4 and tighten it with
a tightening torque (Torque Driver <See Fig. 80>) by 7.5 cNm (0.76 kg f cm).
Fig. E80
View of Head Bottom section
Caution!
Pay attention not to touch the linear
measure sensor tip section when
detaching the diffusion plates.
M1.6×L4
Large Diffusion Plate
Small Diffusion Plate
M1.6×L4
M1.6×L4
Three Bond 1401B
0605-001
5-44