SM-131-006.pdf - 第148页

Device Name Chip Mounter Block Name Page No. Unit Name Revision Model Item GXH -1 Chapter 5 Head Section 7. MSB W hole Cleaning and Lubricat ion Procedures • At the [SETUP] => [NOZ ZLE] tab sheet, perform the nozzle c…

100%1 / 325
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 5 Head Section
7. MSB Whole Cleaning and Lubrication Procedures
(33) Turn on the air, after that turn on the machine and start up the main body.
After the main body starts up, perform all zeroing operation.
Open the [SETUP] => [NOZZLE] tab sheet below <Fig. E83> and set the “Disable”
for the nozzle level teaching. If the “Enable” is set, the machine gets offset operation
automatically when taking the nozzle and the data for “before lubrication” will be
changed. Therefore, the “after lubrication” data can not be compared with the “before
lubrication” ’s one any more.
Fig. E83
Change the
setting to
“Disable”.
0605-001
5-46
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 5 Head Section
7. MSB Whole Cleaning and Lubrication Procedures
At the [SETUP] => [NOZZLE] tab sheet, perform the nozzle change. The heads
cleaned this time will go taking the nozzles used before in the nozzle level teaching
operation. In this case, the order should be the same as before. (No special operation
is required to make the same condition as before.)
Perform the nozzle level offset teaching against the heads cleaned and supplied this
time.
Compare the difference of data between the “after lubrication” and the “before
lubrication” with the teaching result and the difference should be ±0.01mm against
the all nozzles.<Fig. E84>
Fig. E84
When the difference is within ±0.01mm, perform teaching operation for others:
nozzle position offset.
After teaching operation, reset the “Disable” to the “Enable”. Then, this all operations
are completed.
<In case of out of range>
If the difference is not within ±0.01mm, recheck the linear measure sensor attaching direction
and position, soil, damage or etc. otherwise, the bottom rotor section and linear measure
sensor attaching section have trashes and soils or the screw lock (Three Bond 1401B) remains.
Nevertheless, when the problem can not be improved, contact nearest service personnel in our
company.
Before Lubrication data
After Lubrication data
0605-001
5-47
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model Item GXH-1
Chapter 5 Head Section
7. MSB Whole Cleaning and Lubrication Procedures
Recheck after operations are completed.
Fig. E85
Within
±0.01 mm
Yes
No
Teaching results of the nozzle level
teaching between “after lubrication” data
and “before lubrication” data.
Perform the nozzle position offset
teaching and complete this operation.
Recheck after
cleaning of the linear
measure sensor.
Yes
No
Please contact nearest
service
p
ersonnel.
Within
±0.01 mm
0605-001
5-48