Device Name Chip Mounter Block Name Page No. Unit Name Revision Model Item GXH-1 Chapter 7 Transfer Section 3. Setting of PCB Detection Sensor Amplifiers in NA and NC Sections (5) Set the timer function. (Check only if &…

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model ItemGXH-1
Chapter 7 Transfer Section
3. Setting of PCB Detection Sensor Amplifiers in NA and NC Sections
(4) Set the sensitivity.
(Set to "Percent Sensitivity Setting (PH)". Set Level: 50%)
Mode Indication: "SET" ON
Auxiliary Mode Indicator Lamps: OFF
When the D-SW is rotated in this mode, the indication changes as follows.
Press the D-SW.
The settings may become unavailable, depending on how the light is received
during the setting operations. In this case, slightly change the distance of the fiber
for the detection and perform the settings again.
Press the D-SW.
After the detection function is selected, the following condition is set.
Attach the fiber in the "100%" mode desired as a reference.
(PH Flickering)
Set Operation Level Indication "50 to 150%" (the value relative
to one regarded as a reference in the previous operation)
Rotate the D-SW.
Adjustment to Desired Level (50 to 150%):
Press the D-SW.
When the difference in the levels is insufficient, "LE" is turned
ON. When the setting is impossible, "dE" is turned ON.
Rotate the D-SW.
Cancel (-- Flickering)
Press the D-SW.
Press the D-SW.
After the settings are completed, the amplifier is reset to the "Mode Selection" mode.
0406-001
7-9

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model ItemGXH-1
Chapter 7 Transfer Section
3. Setting of PCB Detection Sensor Amplifiers in NA and NC Sections
(5) Set the timer function.
(Check only if "t0 - Momentary" is set.)
Hold down the D-SW for more than 3 seconds.
Mode Indication: "TMR" ON
Auxiliary Mode Indicator Lamps: ON
When the D-SW is rotated in this mode, the
indication changes as follows.
Momentary (t0 Flickering)
Delay Timer (dt Flickering)
One-Shot Timer (1t Flickering)
Cancel (-- Flickering)
Press the D-SW.
Even after the timer function is changed, the time of the timer is kept as it is.
However, when the timer function is changed from "Momentary Output", the OFF
delay timer output or the one-shot ON timer output is selected.
"TMR" Lamp Flickering in "Mode Selection" Mode
0406-001
7-10

Chapter 8
Component Supply Section
This chapter describes how to assemble, replace, and set
up the component supply section.
• Assembly of Feeder Positioning Section
• Replacement of Cylinder and Valve for Feeder Clamping
• Replacement of Feeder Connector
• Replacement of Batch Connector Cable
• Setting of Lifted Feeder Detection Sensor
0406-001 8-A