Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
The linear scale emitted an alarm.
(Cause 1) The speed of the linear scale exceeded the allowable
range.
(Remedy) Change the speed of the linear scale in the
allowable range.
(Cause 2) Some noises are mixed.
(Remedy) Take some countermeasures against noises.
(Cause 3) Alarm from Linear Scale
(Remedy) Inquire the details of the remedial procedures to
the maker of the linear scale.
2A Scale Error 1
(Cause 4) The scale and the detection head are not mounted
correctly in place.
(Remedy) Position the scale and the detection head
correctly.
Permissible regenerative power of the built-in regenerative
brake resistor or regenerative brake option is exceeded.
(Cause 1) Mismatch between used regenerative brake option
and parameter No. 2 setting
(Remedy) Set correctly.
30 Regenerative
error
(Cause 2) Built-in regenerative brake resistor or regenerative
brake option is not connected.
(Remedy) Connect correctly.
17-13
0506-001

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model
Item
GXH-1
Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
(Cause 3) High-duty operation or continuous regenerative
operation caused the permissible regenerative power
of the regenerative brake option to be exceeded.
[Checking Method]: Call the status display and check the
regenerative load ratio.
(Remedy 1) Reduce the frequency of positioning.
(Remedy 2) Use the regenerative brake option of larger
capacity.
(Remedy 3) Reduce the load.
(Cause 4) Power supply voltage is abnormal.
MR-J2S-B: 260 V or more
MR-J2S-B1: 135 V or more
(Remedy) Review power supply.
(Cause 5) Built-in regenerative brake resistor or regenerative
brake option faulty.
(Remedy) Change servo amplifier or regenerative brake
option.
Regenerative transistor fault
(Cause 6) Regenerative transistor faulty.
[Checking Method]: 1) The regenerative brake option has
overheated abnormally.
2) The alarm occurs even after
removal of the built-in
regenerative brake resistor or
regenerative brake option.
(Remedy) Change the servo amplifier.
17-14
0506-001

Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model
Item
GXH-1
Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
Speed has exceeded the instantaneous permissible speed.
(Cause 1) Small acceleration/deceleration time constant
caused overshoot to be large.
(Remedy) Increase acceleration/deceleration time constant.
(Cause 2) Servo system is instable to cause overshoot.
(Remedy 1) Reset servo gain to proper value.
(Remedy 2) If servo gain cannot be set to proper value:
1) Reduce load inertia moment ratio; or
2) Reexamine acceleration/deceleration time
constant.
31 Overspeed
(Cause 3) Encoder faulty.
(Remedy) Change the servo motor.
Current that flew is higher than the permissible current of
the servo amplifier.
(Cause 1) Short occurred in servo amplifier output phases U,
V and W.
(Remedy) Correct the wiring.
(Cause 2) Transistor of the servo amplifier faulty.
[Checking Method]: Alarm (32) occurs if power is
switched on after U, V and W are
disconnected.
(Remedy) Change the servo amplifier.
(Cause 3) Ground fault occurred in servo amplifier output
phases U, V and W.
(Remedy) Correct the wiring.
32 Overcurrent
(Cause 4) External noise caused the overcurrent detection circuit
to misoperate.
(Remedy) Take noise suppression measures.
17-15