Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
Servo motor temperature rise actuated the thermal
protector.
(Cause 1) Ambient temperature of servo motor is over 40°C.
(Remedy) Review environment so that ambient temperature
is 0 to 40°C.
(Cause 2) Servo motor is overloaded.
(Remedy 1) Reduce load.
(Remedy 2) Review operation pattern.
(Remedy 3) Use servo motor that provides larger output.
46 Servo motor
overheat
(Cause 3) Thermal protector in encoder is faulty.
(Remedy) Change servo motor.
Load exceeded overload protection characteristics of servo
amplifier.
Load Factor 300%: 2.5 s or more
Load Factor 200%: 100 s or more
(Cause 1) Servo amplifier is used in excess of its continuous
output current.
(Remedy 1) Reduce load.
(Remedy 2) Review operation pattern.
(Remedy 3) Use servo motor that provides larger output.
50 Overload 1
(Cause 2) Servo system is instable and hunting.
(Remedy 1) Repeat acceleration/deceleration to execute auto
tuning.
(Remedy 2) Change auto tuning response setting.
(Remedy 3) Set auto tuning to OFF and make gain
adjustment manually.
17-20
0506-001
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model
Item
GXH-1
Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
(Cause 3) Machine struck something.
(Remedy 1) Review operation pattern.
(Remedy 2) Install limit switches.
(Cause 4) Wrong connection of servo motor.
Servo amplifier
s output terminals U, V, and W do
not match servo motor
s input terminals U, V, and
W.
(Remedy) Connect correctly.
(Cause 5) Encoder faulty.
[Checking Method]: When the servo motor shaft is rotated
with the servo off, the cumulative
feedback pulses do not vary in
proportion to the rotary angle of the
shaft but the indication skips or
returns midway.
(Remedy) Change the servo motor.
Machine collision or the like caused max. output current to
flow successively for several seconds.
Servo motor locked: 1s or more
(Cause 1) Machine struck something.
(Remedy 1) Review operation pattern.
(Remedy 2) Install limit switches.
51 Overload 2
(Cause 2) Wrong connection of servo motor
Servo amplifier
s output terminals U, V, and W do
not match servo motor
s input terminals U, V, and
W.
(Remedy) Connect correctly.
17-21
0506-001
Device
Name
Chip Mounter
Block Name
Page No.
Unit Name
Revision
Model
Item
GXH-1
Chapter 17 Servo Alarm
1. Troubleshooting on Servo Alarm
Alarm
Codes
Contents of
Servo Alarm
Cause and Remedy
(Cause 3) Servo system is instable and hunting.
(Remedy 1) Repeat acceleration/deceleration to execute auto
tuning.
(Remedy 2) Change auto tuning response setting.
(Remedy 3) Set auto tuning to OFF and make gain
adjustment manually.
(Cause 4) Encoder faulty.
[Checking Method]: When the servo motor shaft is rotated
with the servo off, the cumulative
feedback pulses do not vary in
proportion to the rotary angle of the
shaft but the indication skips or
returns midway.
(Remedy) Change the servo motor.
Droop pulse value of the deviation counter exceeded the
parameter No. 31 setting value (initial value: 2 revolutions).
(Cause 1) Acceleration/deceleration time constant is too small.
(Remedy) Increase the acceleration/deceleration time
constant.
(Cause 2) Torque limit value is too small.
(Remedy) Increase the torque limit value.
(Cause 3) Motor cannot be started due to torque shortage
caused by power supply voltage drop.
(Remedy 1) Review the power supply capacity.
(Remedy 2) Use servo motor which provides larger output.
52 Error excessive
(Cause 4) Position control gain 1 (parameter No.13) value is
small.
(Remedy) Increase set value and adjust to ensure proper
operation.
17-22