EPL6127110_YS12PF_Ope_E - 第148页
Version 1.10 Operator ’ s Manual July 2012

A-1
Appendix
A1. Specifications
n
YS12P/YS12F specifications
Item Specifications
Operating ambient temperature
Function guaranteed: 15 to 35°C
Accuracy guaranteed: 20 to 28°C
Operating ambient humidity 20 to 90% (no condensation), optimal range: 50 to 60%
Noise level Under 78dB
Power requirement (voltage and frequency) 3-phase AC 200/208/220/240/380/400/416 V ± 10%, 50/60 Hz
Average
power
consumption
YS12P 0.8kW
YS12F 1.1kW
Power cable (conductor cross-section area) 2.5 mm
2
or more
Overvoltage category *
1
Category III
Pollution degree *
1
Degree 2
Supply air pressure *
2
0.45MPa
Air flow rate
*6
YS12P/YS12F 120Nl/min, Instantaneous maximum flow rate: 310Nl/min
YS12F+ATS15 130Nl/min, Instantaneous maximum flow rate: 320Nl/min
Board transport height *
3
900 mm ± 10 mm
Data
Number of mounting points *
4
10,000 points
Number of part types 255 types per board
Number of fiducial marks *
5
128 sets per board
*1: Conforms to IEC60664-1.
*2: Clean, dry air passed through an air dryer and filter.
*3: Distance from the floor surface to the upper surface of conveyor belt.
*4: Decreases with the number of boards, blocks and fiducial marks.
*5: When using 2-point fiducial mode.
*6: Air flow rate is for machines with a tape cutter. (Includes 10 Nl for tape cutter.)
c
Conveyor's board sensors may fail to detect a production board if it has a slit or cutout.
n
NOTE
For more detailed information not listed above, please refer to specification sheets.

S-1
Index
A
Alarm buzzer 1-2
ATS15 1-15
Axis configuration 1-19
Blow station 1-20
Board clamping method 2-23
Board production
Ending production 3-11
Pre-operation check 2-18
Resuming operation 3-6
Starting production 3-1
Starting the machine 2-19
C
CE marking i
Component supply section 1-12
Component trays 2-40
Connection between machines 1-2
Conveyor unit 1-18
Conveyor unit setup 2-23
Conveyor width 2-12
[Convey-out stop] button 3-11
[Cycle Stop] button 3-11
Data input unit 1-3
Dummy feeder iv
E
Emergency stop
Canceling emergency stop 2-1
Error
Clearing an error 2-2
Errors and troubleshooting 2-3
Feeder exchange carriage 1-14
Feeder plate 1-12
Air connector 1-12
Power supply connector 1-12
[Feeder Setting] button 2-15
Feeder setup section 1-12
H
Head assembly 1-5
5-in-line multi-head assembly 1-6
K
Keyboard 1-3
Machine main unit 1-1
Names and functions of major parts 1-1
Manual feeder operation 2-15
Manual head operation 2-14
Manual I/O operation 2-16
[Monitor] button 3-13
Mouse 1-3
Multi-vision camera 1-7
N
Nozzle shaft blow 1-21
Nozzle station 1-10
Nozzle types 1-8
Narrow adjacent type 1-9
Standard type 1-8
Operation panel 1-3
[READY] button 2-1
Operation panel buttons 1-4
[ACTIVE] button 1-4
[EMERGENCY STOP] button 1-4
[ERROR CLEAR] button 1-4
[READY] button 1-4
[RESET] button 1-4
[START] button 1-4
[STOP] button 1-4
Operation screen 2-8
Menu button area 2-8
Status area 2-8
Operation speed 3-3
[Operator] button 2-20
P
Pallet 1-16
Setting a pallet 2-41
Password 2-20
Pick Rate Warning 3-27
Pickup position offset 3-25
Power station for the offline setup 2-26
Power switch 1-2,2-19
Turning power off 3-11
Pressure gauge 1-2
Production monitors 3-13
Push-up pin 2-25
R
Recognition system 1-18
Return-to-origin 2-19
S
Safety ii
Safety cover 1-2
Safety message vii
Scan camera 1-7
Setup screen 2-11,3-2
[Check Nozzles] button 3-3
[Feed Bulk] button 3-3
[Measure Nozzles] button 3-3
[Required Nozzles] button 3-3
[Required Parts] button 3-2
set-up station on machine 2-26,2-33
Side-view function 1-7
Signal light 1-2
Specifications A-1
T
Tape cutter 1-26
Tape feeder
Disposing of used top tape 3-4
Operation check 2-47
Setting a tape feed pitch 2-31
Settings on the mounter side 2-42
Setting the tape 2-26
Tray changer 1-15
Tray components 2-40
U
Unit screen 2-12
W
Warm-up 2-21
[Warm Up] button 2-21
Warning labels xi
"watch-and-wait" mode 3-29

Version 1.10
Operator’s Manual July 2012