EPL6127110_YS12PF_Ope_E - 第98页

2-33 2  asic operation n Setting a pitch from each station T he following describes how to set up tape feed pitch with a set-up station on mac hine or a P ower station for the offline setup, LED indications of stations …

100%1 / 148
2-32
2
asic operation
4
Set the tape feed pitch.
From the "Feed Pitch" drop-down list, select the feed pitch that matches the components in the feeder,
and then press the [OK] button.
Setting the tape feed pitch
Example of YS12F
24221-L7-00
5
Check the tape feed operation.
Press the [Feed] button on the lower right of the screen to check that the tape is fed at the pitch you
set.
Checking the feed pitch
Example of YS12F
24222-L7-00
2-33
2
asic operation
n
Setting a pitch from each station
The following describes how to set up tape feed pitch with a set-up station on machine or a Power station for
the offline setup, LED indications of stations and error indications.
1
Check the tape feed pitch of the feeder.
The tape feed pitch is indicated on the display as shown below.
Checking the tape feed pitch
Display
23213-L6-00
2
Set the tape feed pitch.
Press the [UP] or [DOWN] button to set the feed pitch that matches the components in the feeder, and
then press the [SET] button to determine the setting.
Setting the tape feed pitch
[SET][UP] [DOWN]
23214-L6-00
2-34
2
asic operation
3
Check the tape feed operation.
Press the [FEED] button on the feeder body to check that the tape is fed at the correct pitch.
c


advance the carrier tape.
TIP
• Thefeedpitchwillalwaysbe2mmeachtimethe[FEED]or[BACK]buttononthefeederbodyispressed,
regardless of the pitch setting. Holding down either of these buttons feeds the tape continuously.
• Usethe[FUNC]+[FEED]buttonstofeedthetapeatthefeedpitchthatwasset.
Checking the feed pitch
[BACK] button
[FEED] button[FUNC] button
23215-L6-00