00193794-11_VD_SSW 505.05_de en - 第18页
Software Version Description, Station Software 505.05 07/2008 Edition 18 of 150 3.2.3 Station computer 3.2.3.1 Station computer HF, HF/3 Name Simicro CPU076 CPU / clock frequency PIII / 866 MHz or 1,26 GHz RAM memory 192…

Software Version Description, Station Software 505.05 07/2008 Edition
3.2.2 Network configuration
HF, HF/3 machine
SIPLA CE Pro
Station computer Machine controller
10Base-T
GEM host
10Base-T
100Base-T
Private netw ork between
station computer and
machine controller
SIPLA CE LAN
Fig. 3-4: Network connections between the machine, SIPLACE Pro and GEM host (optional) Example: (SIPLACE HF and HF/3)
A separate private network (100Mbit) is set up between the station computer and the machine
controller via a subnet mask.
Fixed IP addresses for the station computer and the machine controller can thus be assigned for all
SIPLACE machines. These IP addresses are not known outside the private network, for instance in the
SIPLACE LAN.
These IP addresses need not be further configured by the operator while the station software is being
installed.
IP address, station computer 192.168.255.249
IP address, machine controller 192.168.255.250
Subnet mask, station computer/machine controller 255.255.255.248
IP address range, SIPLACE LAN 172.22.xxx.xxx
Subnet mask, SIPLACE LAN 255.255.0.0
Table 3-1: Network configuration
17 of 150

Software Version Description, Station Software 505.05 07/2008 Edition
18 of 150
3.2.3 Station computer
3.2.3.1 Station computer HF, HF/3
Name Simicro CPU076
CPU / clock frequency PIII / 866 MHz or 1,26 GHz
RAM memory 192 MB
Hard disk 6 GB
CD-ROM drive Yes
Floppy drive 3.5", 1.44 MB
Serial interfaces 2
Network 1 x 10/100Base-T
2 x 10Base-T
6-port hub
Table 3-2: Station computer hardware
3.2.3.2 Station computer S-25 HM, S-27 HM
Name SCENIC N 300
CPU / clock frequency PIV / 2.4 GHz
RAM memory 256 MB
Hard disk 40 GB
CD-ROM drive Yes
Floppy drive 3.5", 1.44 MB
Serial interfaces 2
Network 1 x 10/100Base-T
1 x 10Base-T
Table 3-3: Station computer hardware
3.2.3.3 Station computer HS-50, HS-50+, HS-60
Name SCENIC P 300
CPU / clock frequency PIV / 2.6 GHz
RAM memory 256 MB
Hard disk 40 GB
CD-ROM drive Yes
Floppy drive 3.5", 1.44 MB
Serial interfaces 2
Network 1 x 10/100Base-T
2 x 10Base-T
6-port hub
Table 3-4: Station computer hardware

Software Version Description, Station Software 505.05 07/2008 Edition
19 of 150
3.2.4 Machine controller
3.2.4.1 Machine controller HF, HF/3
Name Simicro CPU076
CPU / clock frequency PIII / 566 MHz
RAM memory 64 MB
Hard disk 6 GB
CD-ROM drive Yes
Floppy drive 3.5", 1.44 MB
Network 1 x 10/100Base-T
Table 3-5: Machine controller hardware
3.2.4.2 Machine controller S-25 HM, S-27 HM, HS-50, HS-50+, HS-60
Name Sicomp AMS – M54
CPU / clock frequency PI / 233 MHz
RAM memory 32 MB
Hard disk 504MB
CD-ROM drive No
Floppy drive 3.5", 1.44 MB
Network 1 x 10/100Base-T
Table 3-6: Machine controller hardware