00193794-11_VD_SSW 505.05_de en - 第29页

are 505.05 07/2008 Edition 29 of 150 Feature HS-50 HS-50+ HS-60 S-25 HM S-27 HM HF/3 HF SC softw are, basic version SC softw are, full ve rsion A dditional information Check of the hold ing- circuit v acuum 9 Enhancement…

100%1 / 150
Software Version Description, Station Software 505.05 07/2008 Edition
Feature HS-50 HS-50+ HS-60 S-25 HM S-27 HM HF/3 HF SC SC Additional
information software, software,
basic
full
version
version
Coplanarity module
9 9 9
"coplanarity
module" option
(hardware)
required
Dip module
Advantage: Flexibility
9 9 9 9 9
Dip module
hardware option
required
Component reject
conveyor
Advantage: Lower
placement costs
9 9 9 9 9 9 9 9
Component
reject conveyor
option
(hardware)
required
Flexible feeder interface
(FFI)
Advantage: Flexibility
9 9 9 9 9 9 9 9
Support for bulk-case
feeder
Advantage: Flexibility
9 9 9 9 9 9 9 9
Feeder hardware
required
Support for surf tape
feeder
Advantage: Flexibility
9 9 9 9 9 9 9 9
Feeder hardware
required
Fault –tolerant run-up of
the subsystems
9
Wide conveyor for the
HS-60
9
Whispering of ink spots
9
Cage resetting for THK
guide
9
Ball race monitoring
9 9 9 9 9
9
only for
12-seg. C&P
28 of 150
are 505.05 07/2008 Edition
29 of 150
Feature HS-50 HS-50+ HS-60 S-25 HM S-27 HM HF/3 HF SC
software,
basic
version
SC
software,
full
version
Additional
information
Check of the holding-
circuit vacuum
9
Enhancement of the
station software to
include conveyor-related
items
9
All features of versions
502 / 503 / 504 are
supported
Advantage: Compatibility
9 9 9 9 9 9 9 9
Error corrections for
version 503
9 9 9 9 9
9
Error corrections for
version 504 *
9 9
Error corrections for
version 505.01 through
505.04 SP2
9 9 9 9 9 9 9 9
* The basic version of the SC 505.03 software is the officially corrected version of the SC 504 software
Software Version Description, Station Softw
Software Version Description, Station Software 505.05 07/2008 Edition
5.2 Improved error detection for "missing nozzles"
A monitoring function is implemented to detect immediately missing nozzles on the placement head.
Then a fatal machine error is displayed.
In this case check the PCB and the segment and reset the nozzle. The placement process can be
continued.
Restrictions
The function depends on the nozzle type and is not supported for all nozzle types, see the table
below.
PipTyp
VakSchwellwert
VakGrenzwert
VakOffenAbh
VakCheckMode
ZhoehenMin
ZhoehenMax
ZcheckMode
MinVakDeltaOffenZu
PipZSchwellwert
PipCheckMode
901 2000 30 55 1 200 1000 1 55 4000 3
902 -1 -1 0 0 0 0 0 0 4000 3
904 4000 40 100 1 500 1000 1 120 5000 3
906 -1 -1 0 0 0 0 0 0 4000 3
911 2000 30 55 1 200 1000 1 55 4000 3
913 -1 -1 0 0 0 0 0 0 5500 3
914 4000 40 100 1 500 1000 1 120 5000 3
915 -1 -1 0 0 0 0 0 0 6000 3
923 -1 -1 0 0 0 0 0 0 5000 3
924 -1 -1 0 0 0 0 0 0 5000 3
925 2000 30 55 1 200 1000 1 50 4000 3
30 of 150