00193794-11_VD_SSW 505.05_de en - 第30页

Software Version Description, Station Software 505.05 07/2008 Edition 5.2 Improved error detection for "missing nozzles" A monitoring function is implemented to detect i mmediately missing nozzles on the placem…

100%1 / 150
are 505.05 07/2008 Edition
29 of 150
Feature HS-50 HS-50+ HS-60 S-25 HM S-27 HM HF/3 HF SC
software,
basic
version
SC
software,
full
version
Additional
information
Check of the holding-
circuit vacuum
9
Enhancement of the
station software to
include conveyor-related
items
9
All features of versions
502 / 503 / 504 are
supported
Advantage: Compatibility
9 9 9 9 9 9 9 9
Error corrections for
version 503
9 9 9 9 9
9
Error corrections for
version 504 *
9 9
Error corrections for
version 505.01 through
505.04 SP2
9 9 9 9 9 9 9 9
* The basic version of the SC 505.03 software is the officially corrected version of the SC 504 software
Software Version Description, Station Softw
Software Version Description, Station Software 505.05 07/2008 Edition
5.2 Improved error detection for "missing nozzles"
A monitoring function is implemented to detect immediately missing nozzles on the placement head.
Then a fatal machine error is displayed.
In this case check the PCB and the segment and reset the nozzle. The placement process can be
continued.
Restrictions
The function depends on the nozzle type and is not supported for all nozzle types, see the table
below.
PipTyp
VakSchwellwert
VakGrenzwert
VakOffenAbh
VakCheckMode
ZhoehenMin
ZhoehenMax
ZcheckMode
MinVakDeltaOffenZu
PipZSchwellwert
PipCheckMode
901 2000 30 55 1 200 1000 1 55 4000 3
902 -1 -1 0 0 0 0 0 0 4000 3
904 4000 40 100 1 500 1000 1 120 5000 3
906 -1 -1 0 0 0 0 0 0 4000 3
911 2000 30 55 1 200 1000 1 55 4000 3
913 -1 -1 0 0 0 0 0 0 5500 3
914 4000 40 100 1 500 1000 1 120 5000 3
915 -1 -1 0 0 0 0 0 0 6000 3
923 -1 -1 0 0 0 0 0 0 5000 3
924 -1 -1 0 0 0 0 0 0 5000 3
925 2000 30 55 1 200 1000 1 50 4000 3
30 of 150
Software Version Description, Station Software 505.05 07/2008 Edition
932 -1 -1 0 0 0 0 0 0 4200 3
933 -1 -1 0 0 0 0 0 0 5500 3
934 -1 -1 0 0 0 0 0 0 5000 3
935 -1 -1 0 0 0 0 0 0 6000 3
936 -1 -1 0 0 0 0 0 0 5500 3
PipZSchwellwert: Threshold value as of which the nozzle is detected as missing
(Z_actual – Z_target >= Z_Threshold)
PipCheckMode:
0:off
1: on (warning in case of error)
2: Machine immediately on (FE, fatal error);
3 Machine stops after head cyclus mit FE
4: Fatal error (head reference run)
5.3 Connection of line computers and monitoring of the MaDaMas
data
As of this station software version it is possible to connect line computers as of the line computer
version 503.06 (Item no. 00193520-xx) for the following machines:
- HS-50, HS-60
- S-25, S-27
There, any features of the station software 503 are supported.
Restrictions
The connection of the line computers is not possible for the machines HF and HF3.
31 of 150